SCSI Commands: 33BRECEIVE DIAGNOSTIC RESULTS
Page
151
3.21.4.1
Field Descriptions – PCV not set
Field
Bytes
Bits
Description
Page Code
0
Identifies the type of diagnostic page being returned.
Reserved
1
All reserved bits must be 0.
Page Length
2-3
Indicates the number of bytes of data to be returned after this block.
Transfer
Period Factor
4
Transfer Period Factor is the same as the one found in PPR and SDTR messages.
Reference the SPI specification for further details on how to derive the Transfer
Period from the Transfer Period Factor.
Req/Ack
Offset
6
Req/Ack Offset is the same as the one found in PPR and SDTR messages.
Reference the SPI specification for further details.
Transfer
Width
Exponent
7
Transfer Width Exponent
0 = narrow
1 = wide
PCOMP_EN 8
7 Precompensation
enable
RTI
8
6
Retain training information
RD_STRM
8
5
Read streaming and read flow control enable
WR_FLOW
8
4
Write flow control enable
HOLD_MCS
8
3
Hold margin control settings
QAS_REQ
8
2
Always 0, indicating Quick Arbitration and Select is not supported
DT_REQ
8
1
DT clocking enable request.
Set to one when a double transition transfer agreement is in effect.
IU_REQ
8
0
Information units enable request
3.21.5
RECEIVE DIAGNOSTIC RESULTS Completion Status
Status Message Description
00h
Good
Status
The drive is ready to perform any appropriate command.
The drive remains in any previously set mode.
The tape position is not changed.
02h
Check
Condition
Use the REQUEST SENSE command to retrieve status information. Possible
Sense Keys are:
Code Message
Description
04h
Hardware Error
Drive hardware failure detected.
05h
Illegal Request
The CDB contains an invalid bit.
06h
Unit Attention
The cartridge was changed, or the drive was
reset prior to this command.