SRV_MOTOR_POR_STUCK_1
3F4h
Servo
can't clear reel motor POR flag on startup
SRV_MOTOR_POR_STUCK_2
3F5h
Servo
can't clear reel motor POR flag after PF clear
SRV_MOTOR_PWR_FAIL 3F6h
Servo
can't
clear
reel motor power fail condition on startup
SRV_STATEM_AUTOLOAD_COMMAND_REJECTED_N
O_CART_IN_DRIVE
3F7h Servo Autoload
failed
SRV_SZA_LOAD_COMPLETION_FAILURE 3F8h
Servo
SZA
load function did not complete in the allotted time
SRV_TAPE_CUT 3F9h
Servo
tape
cut
SRV_MOVETAPE_ERROR_LP1_UNDERRUN_DURING
_RAMP_UP
3FAh
Servo
LP1 Underrun during ramp up state
SRV_MOVETAPE_ERROR_LP6_OVERRUN_DURING_
RAMP_UP
3FBh
Servo
LP6 overrun during ramp up
SRV_MOVETAPE_RAMP_DOWN_API_FAILED_DURIN
G_ERROR_HANDLING
3FCh
Servo
Ramp down api failed during error handling
SRV_MOVETAPE_LP1_UNDERRUN_IN_CRUISE_CON
TROL
3FDh
Servo
LP1 underrun during cruise control state.
SRV_MOVETAPE_LP6_OVERRUN_IN_CRUISE_CONT
ROL
3FEh
Servo
LP6 overrun in cruise control state.
SRV_CMDPROC_NO_CARTRIDGE_IN_DRIVE
3FFh
Servo
No cartridge in drive
SRV_STEP_HEAD_TRIGGERED_SENSORS_DURING_
HEAD_STEPPING
400h
Servo
Top or bottom sensors for head stepper were triggered when
they shouldn't have b
SRV_STEP_HEAD_NOT_AT_BASEMENT_POSITION 401h Servo
SRV_STEP_HEAD_COULD_NOT_FIND_PES_DURING_
HEAD_CALIBRATION
402h Servo
SRV_STEP_HEAD_PES_CAPTURE_IS_BAD_DURING_
HEAD_CALIBRATION
403h
Servo
Max retries exceeded to verify PES during head offset cal.
SRV_STEP_HEAD_INCORRECT_OFFSET_FROM_HEA
D_CALIBRATION
404h Servo
SRV_ROTATE_ENABLEMOTOR_API_REJECT_BUSY 405h
Servo
Enable Motor API failed at beginning of Rotate command
SRV_EXCEED_LC_LIMIT 406h
Servo
exceed
LC
limit
SRV_RAD_COMP_ERR 407h
Servo
radius
computation
off
SRV_TAPE_SLACK 408h
Servo
tape
slack
SRV_HIT_EOT 409h
Servo
hit
EOT
SRV_HIT_PEOT 40Ah
Servo
hit
PEOT
SRV_WATCH_DOG
40Bh
Servo
Watch Dog Timer Interrupt
SRV_EXCEPT_UNDEF_INSTR 40Ch
Servo
Undefined
exception
SRV_EXCEPT_PREFECT 40Dh
Servo
Prefect
exception
SRV_EXCEPT_MEMORY_ABORT 40Eh
Servo
Memory
abort
exception
SRV_EXCEPT_SOFTWARE_INTERRUPT 40Fh
Servo
Software interrupt exception
SRV_EXCEPT_EXCEPTION_CODE_OUT_OF_RANGE 410h
Servo
Software exception identifier out of range
SRV_GLOBAL_ERROR_STATE 411h
Servo
Firmware global error state
SRV_REEL_PHYSICAL_EOT_LIMIT_OVERRUN_IN_HO
LD_STATE
412h
Servo
Physical eot limit overrun occured in hold state
SRV_REEL_PHYSICAL_BOT_LIMIT_UNDERUN_IN_HO
LD_STATE
413h
Servo
Physical bot limit underrun occured in hold state
SRV_REEL_LP1_LIMIT_UNDERUN_IN_HOLD_STATE
414h
Servo
LP1 limit underrun in hold state
SRV_REEL_LP6_LIMIT_OVERRUN_IN_HOLD_STATE 415h
Servo
LP6 limit overrun in hold state
SRV_SEQ_PAST_EOT_REJ_INV_STATE_BETWEEN_E
OT_AND_PEOT
416h
Servo
LPOS is past EOT based on ratiometric EOT detection
SRV_REEL_INVALID_TASK_FOR_MESSAGE_RESPO
NSE
417h
Servo
Sender id not valid for sending a message to
SRV_STATEM_SEQUENCER_STACK_OVERFLOW 418h Servo
Sequencer control stack overflowed.
SRV_SEQ_STACK_UNDERFLOW 419h
Servo
Sequencer control stack underflowed.
SRV_SEQ_PAST_EOT_REJ_INV_STATE_EXCEEDING
_PEOT
41Ah
Servo
Tape exceeds EOT per ratiometric calculation of position
SRV_MOVETAPE_UNEXPECTED_LPOS_NOTIFICATIO
N_IN_RAMP_UP_STATE
41Bh
Servo
An LPOS notification occured during ramp up
SRV_MOVETAPE_UNRECOGNIZED_COMMAND_IN_R
AMP_UP_STATE
41Ch
Servo
Unrecognized command detected at speed in ramp up state
SRV_STEP_HEAD_COULD_NOT_FIND_ANY_PES_DU
RING_HEAD_CALIBRATION
41Dh
Servo
No PES found during head offset calibration command.
Summary of Contents for LTO 4
Page 1: ......