SCSI Commands: 22BMODE SELECT
Page
103
Field
Bytes
Bits
Description
INQUIRY
String Control
5
0 = Standard INQUIRY string (default)
1 = Factory test only INQUIRY string 1
2 = Factory test only INQUIRY string 2
3 = Factory test only INQUIRY string 3
Firmware Test
Control
6
0 = disable Factory test mode code (default)
1 = enable Factory test code 1
2 = enable Factory test code 2
Data
Compression
Control
7
0 = Full Mode Page 0Fh & 10h Control of Compression (default)
1 = Auto compression with No SCSI Mode control
2 = Compression Disabled with No SCSI Mode control
Host Unload
Override
(HUO)
8
7
The Host Unload Override:
0 = Host Unload command will eject the cartridge
1 = Hose Unload command will NOT eject the cartridge
Library systems that do not want the host to eject the cartridge
should set this bit.
Auto Unload
Mode
8 0-6
The Auto Unload Mode allows the drive to control how the tape is
unloaded when (a) a power cycle occurs with a tape inside, (b) an
incompatible tape is inserted, (c) a firmware download occurs with
a tape inside, and (d) the cleaning tape has finished the cleaning
process. Refer to section on Library Features – Auto Unload
Mode for additional details.
0 = Data cartridge stays threaded at BOM; do not unthread and do
not unload. (default)
1 = Unthread.
2 = Unthread and unload.
3 = Unthread and unload non-data cartridges, data cartridges are
threaded to BOM. (Basically data cartridges behave as for
mode 0 and non-data cartridges behave according to mode 2.
4 = Unthread and unload non-data cartridges except expired
cleaning cartridge remain seated. Data cartridges are
threaded to BOM.
Firmware Test
Control 3
9
0 = disable Factory test mode code (default)
1 = enable Factory test code 1
2 = enable Factory test code 2
Firmware Test
Control 4
10
00h = Factory Settings
01h = Factory Settings
02h = Factory Settings
03h = Factory Settings
04h = Factory Settings
05h = Factory Settings
Reserved
All reserved bits must be 0.
Summary of Contents for LTO 4
Page 1: ......