Chapter 9: Troubleshooting
291
Blowers are functioning
normally
Normal.
Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it.
See page 238.
Blower status is unknown Check for airflow out of the cooling unit. If there is
none, check for proper installation.
Cache
BBU flushing has started
VessRAID’s cache is being flushed.
BBU flushing has ended
VessRAID’s cache has been flushed.
BBU flushing has failed
VessRAID’s cache could not be flushed. Check your
cache flush interval setting. See page 96 (WebPAM
PROe) or page 147 (CLU).
Controller
The controller
parameter(s) changed by
user
The user successfully changed controller settings.
See page 96 (WebPAM PROe) or page 147 (CLU).
The controller has new
crash information
Check the event logs. See page 53 and 54 (WebPAM
PROe) or page 186 (CLU)
Controller temperature is
above the threshold/
warning threshold
The VessRAID controller is overheating. Check for
airflow around and through the controller, and verify
that all fans are working. Replace fans as needed.
Controller temperature is
above the critical
threshold
The VessRAID controller is seriously overheating.
Check for airflow around and through the controller,
and verify that all fans are working. Replace fans as
needed.
Disk Array
New disk array has been
created
Result of settings or user action. Normal.
Disk array has been
deleted
Result of settings or user action. Normal.
Disk array has been
added
Result of settings or user action. Normal.
Disk array has been
removed
The physical drives of the disk array were removed
from the enclosure.
Disk array settings have
been changed
The user successfully disk array settings. See
page 120 (WebPAM PROe) or page 163 (CLU).
Reported Event
Corrective Action
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...