Chapter 4: Management with WebPAM PROe
57
•
Reassigned Block Threshold – 1 to 512 blocks
•
Error Block Threshold – 1 to 1024 blocks
5.
Check to enable or uncheck to disable the following functions:
•
Media Patrol – Checks the magnetic media on physical drives
•
Auto Rebuild – If there is a spare drive of adequate capacity, a critical
disk array will begin to rebuild automatically. If not spare drive is
available, the disk array will begin to rebuild as soon as you replace the
failed physical drive with an unconfigured physical drive of equal or
greater size.
6.
Click the Submit button to save your settings.
Running Background Activities
To run a background activity from the Background Activities tab:
1.
In Tree View, click the Subsystem
icon.
2.
In Management View, click the Background Activities tab and choose one
of the following from the dropdown menu.
•
Media Patrol – See “Running Media Patrol” on page 57
•
Rebuild – See “Rebuilding a Disk Array” on page 123
•
PDM – See “Running PDM” on page 58
•
Transition – See “Transitioning a Disk Array” on page 125
•
Initialization – See “Initializing a Logical Drive” on page 129
•
Redundancy Check – See “Running Redundancy Check” on page 130
3.
In the next screen, make the choices as requested.
4.
Click the Start button.
Running Media Patrol
Media Patrol checks the magnetic media on physical drives. When it finds the
specified number of bad blocks, it will trigger PDM. See “Making Background
Activity Settings” on page 56 and “Running PDM” on page 58.
You can schedule Media Patrol to run automatically, see “Scheduling an Activity”
on page 58.
To run Media Patrol:
1.
In Tree View, click the Subsystem
icon.
2.
From the dropdown menu on the Background Activities tab, choose Start
Media Patrol.
3.
In the next screen, click the Start button.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...