![Promise Technology VessRAID 1720i Product Manual Download Page 271](http://html.mh-extra.com/html/promise-technology/vessraid-1720i/vessraid-1720i_product-manual_1617199271.webp)
Chapter 8: Technology Background
255
RAID 60 Axles
When you create a RAID 60, you must specify the number of axles. An axle
refers to a single RAID 6 logical drive that is striped with other RAID 6 logical
drives to make RAID 60. An axle can have from 4 to 16 physical drives,
depending on the number of physical drives in the logical drive.
The chart below shows RAID 60 logical drives with 8 to 20 physical drives, the
available number of axles, and the resulting distribution of physical drives on
each axle.
RAID 60 Logical Drive
No. of
Drives
No. of
Axles
Drives per
Axle
No. of
Drives
No. of
Axles
Drives per
Axle
8
2
4,4
17
2
8,9
9
2
4,5
3
5,6,6
10
2
5,5
4
4,4,4,5
11
2
5,6
18
2
9,9
12
2
6,6
3
6,6,6
3
4,4,4
4
4,4,5,5
13
2
6,7
19
2
9,10
3
4,4,5
3
6,6,7
14
2
7,7
4
4,5,5,5
3
4,5,5
20
2
10,10
15
2
7,8
3
6,7,7
3
5,5,5
4
5,5,5,5
16
2
8,8
5
4,4,4,4,4
3
5,5,6
4
4,4,4,4
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...