VessRAID 1000i Series Product Manual
206
Starting Up After Shutdown
There are two methods for shutting down the subsystem. Choose one:
•
Starting up the VessRAID – Telnet Connection (page 206)
•
Starting up the VessRAID – Serial Connection (page 206)
Starting up the VessRAID – Telnet Connection
To start the RAID subsystem:
1.
Manually turn on the power supply switches on the back of the subsystem.
If the switches are ON but the subsystem is OFF, turn the switches off and
on again.
On subsystems with redundant power supplies, if the power switches do not
respond, unplug the power cords and plug them back in. Try the power
switches again.
2.
Wait about two minutes.
3.
Establish a Telnet connection to the VessRAID.
See “Making a Telnet Connection” on page 141.
If you cannot log in, wait 30 seconds and try again.
4.
Type menu and press Enter to open the CLU.
Starting up the VessRAID – Serial Connection
To start the RAID subsystem:
1.
Manually turn on the power supply switches on the back of the subsystem.
If the switches are ON but the subsystem is OFF, turn the switches off and
on again.
On subsystems with redundant power supplies, if the power switches do not
respond, unplug the power cords and plug them back in. Try the power
switches again.
2.
Wait about two minutes.
3.
Establish a serial connection to the VessRAID.
See “Making a Serial Connection” on page 140.
When the Login: prompt appears, the start up is finished.
4.
Type menu and press Enter to open the CLU.
Important
If you have a JBOD Expansion, always power on the JBOD
subsystems first. Then power on the RAID subsystem.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...