VessRAID 1000i Series Product Manual
22
JBOD Expansion to DAS or SAN
The 16- and 12-bay VessRAID models have a JBOD expansion port.
JBOD expansion is not possible with 8-bay VessRAID models.
Configuring a Data Path
To establish the data path:
1.
Connect the SAS Expansion port (with a diamond icon) of the VessRAID
controller to the SAS IN port (with a circle icon) on the I/O module of the first
VessJBOD.
2.
Connect the SAS OUT port (with a diamond icon) of the VessJBOD I/O
module of the first VessJBOD to the SAS IN port (with a circle icon) on the
I/O module of the second VessJBOD.
3.
Connect the remaining VessJBOD units in the same manner.
Be sure to connect circle icon to diamond icon and vice versa.
All SAS ports have SFF-8088 connectors. SAS cables are not included.
Figure 14.JBOD expansion to DAS and SAN
This completes data and management connections.
SAS Expansion port
Diamond icon
SAS OUT port
Diamond icon
SAS IN port
Circle icon
SAS IN port
Circle icon
VessRAID
VessJBOD
VessJBOD
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...