![Promise Technology VessRAID 1720i Product Manual Download Page 133](http://html.mh-extra.com/html/promise-technology/vessraid-1720i/vessraid-1720i_product-manual_1617199133.webp)
Chapter 4: Management with WebPAM PROe
117
The following parameters display:
•
Disk Arrays – The number of physical drives in the disk array, their slot
numbers, configurable capacity, and the number of logical drives to be
created
•
Logical Drives – The slot number of the logical drive(s), their RAID
level, capacity, and stripe size
•
Spare Drives – The physical drive slot number of the dedicated hot
spare assigned to this disk array (all RAID levels except RAID 0)
If you have both Hard Disk Drives (HDD) and Solid State Drives (SSD),
separate disk arrays will be created for your HDDs and for your SSDs. Each
array will have the number of logical drives that you specified.
If you accept these parameters, proceed to the next step. If NOT, review and
modify your selections in the previous steps.
9.
When you are done, click the Submit button.
The new disk array appears in the Disk Array List the Information tab.
Creating a Disk Array – Advanced
The Disk Array Advanced Creation option enables you to directly specify all
parameters for a new disk array. One logical drive will be made automatically
when you create the disk array. If you choose less than the total available
capacity, you can use the remaining space to create additional logical drives at a
later time.
If you are uncertain about choosing parameters for your disk array, use the
Express or Automatic option to create your disk array.
To create a new disk array:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
From the Create tab dropdown menu, choose Advanced.
Step 1 – Disk Array Creation
1.
Enter an alias for the disk array in the field provided.
2.
Check the boxes to enable the following features.
•
Media Patrol – A routine maintenance procedure that checks the
magnetic media on each disk drive. Media Patrol is concerned with the
condition of the media itself, not the data recorded on the media.
•
PDM – Predictive Data Migration (PDM) scans the bad sector
remapping table of the disk drives assigned to a logical drive. When the
table fills to a specified percentage of its capacity, PDM triggers a
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...