Chapter 5: Management with the CLU
159
Creating a Disk Array – Automatic
To create a disk array using the Automatic feature:
1.
From the Main Menu, highlight Disk Array Management and press Enter.
2.
Highlight Create New Array and press Enter.
3.
Highlight Configuration Method and press the spacebar to toggle to
Automatic.
4.
Review the proposed configuration of disk array and logical drive(s).
•
To accept the proposed configuration and create the disk array and
logical drive(s), highlight Save Configuration and press Enter.
•
To reject the proposed configuration, highlight Cancel Array
Configuration and press Enter. You will return to the Disk Arrays
Summary screen.
To create a disk array with different characteristics, repeat the steps
above specifying different parameters but choose the Express or
Advanced option.
If you have both Hard Disk Drives (HDD) and Solid State Drives (SSD),
separate disk array and logical drive sets will be created for your HDDs
and for your SSDs. These two drive types cannot be mixed in the same
disk array.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...