VessRAID 1000i Series Product Manual
292
Drive Interface Controller
Drive-interface controller
found
Normal.
Drive-interface controller
is NOT found
Restart the VessRAID. See page 94 (WebPAM
PROe) or page 207 (CLU). If this message appears
repeatedly, contact Technical Support. See page 319.
Drive-interface
diagnostics has passed
Normal.
Drive-interface
diagnostics has failed
Restart the VessRAID. See page 94 (WebPAM
PROe) or page 207 (CLU). If this message appears
repeatedly, contact Technical Support. See page 319
Drive-interface controller
has generated a general/
data parity error.
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support. See
page 319.
Enclosure
Enclosure temperature is
above the threshold/
warning threshold
The VessRAID is overheating. Check for airflow
around and through the VessRAID, and verify that all
fans are working. Replace fans as needed.
Enclosure temperature is
above the critical
threshold
The VessRAID is seriously overheating. Check for
airflow around and through the VessRAID, and verify
that all fans are working. Replace fans as needed.
Enclosure temperature is
within the normal range
Normal.
Event Log
Event logging is enabled
Event logging has been successfully enabled.
Event logging is disabled
Event logging has been disabled.
Event log buffer is cleared
in RAM
The event log was cleared.
Event log buffer is cleared
in NVRAM
The non-volatile RAM event log was cleared.
Event log buffer is cleared
in MDD
The MDD (disk drive) event log was cleared.
Host Interface Controller
Host-interface controller
has detected bus reset
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support. See
page 319.
Reported Event
Corrective Action
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...