VessRAID 1000i Series Product Manual
204
Shutting Down the Subsystem
There are two methods for shutting down the subsystem, depending on your
connection. Choose the applicable procedure:
•
Shutting down the VessRAID – Telnet Connection (page 204)
•
Shutting down the VessRAID – Serial Connection (page 205)
Shutting down the VessRAID – Telnet Connection
This function enables you to shutdown the VessRAID subsystem on a Telnet
connection. Additional action is required, as described below.
To shutdown the VessRAID:
1.
From the Main Menu, highlight Additional Info and Management and press
Enter.
2.
Highlight Shutdown or Restart and press Enter.
3.
Do one of the following actions:
•
Highlight Option and press the spacebar to display Shutdown.
•
Highlight Option and press the spacebar to display Poweroff.
4.
Highlight Submit and press Enter.
A warning message appears.
5.
Press Y to continue.
The screen goes blank.
6.
Wait for no less than two minutes.
7.
Do one of the following actions:
•
If you chose the Shutdown Option, manually turn off the power supply
switch (both switches with redundant power supplies) on the back of the
subsystem.
•
If you chose the Poweroff Option, the subsystem powers down
automatically. On subsystems with redundant power supplies, unplug
the power cords and plug them back in, to activate the power switches.
•
Important
If you have a JBOD Expansion, always power off the RAID
subsystem first. Then power off the JBOD subsystems.
Caution
After you power off the subsystem, wait at least 10 seconds before
you power on the subsystem again.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...