VessRAID 1000i Series Product Manual
102
3.
Click the Enclosure
icon.
4.
Click the FRU VPD tab in Management View.
Use this information when communicating with Technical Support and when
ordering replacement units. For contact information, see “Contacting Technical
Support” on page 319.
Checking the Battery
A cache backup battery or Battery Backup Unit (BBU) is optional on VessRAID.
To check the battery:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Enclosures
icon.
3.
Click the Enclosure
icon.
4.
Click the Battery tab in Management View.
Battery Notes
Each battery works with a controller. If the battery is present in the subsystem but
the corresponding controller is not present, the battery will not appear in the
interface.
If a battery does not reflect normal conditions and it is not currently under
reconditioning, run the Recondition function before you replace the battery. See
“Reconditioning a Battery” on page 103.
Reconditioning fully discharges, then fully recharges the battery. During
reconditioning, if the Adaptive Writeback Cache function is enabled, the controller
cache is set to Write Thru. After reconditioning, the cache is reset to Write Back.
See “Making Controller Settings” on page 96.
If a battery reaches the threshold temperature while charging or discharging, the
charge or discharge pauses and the blower runs at high speed until the battery
temperature falls below the threshold.
If the battery does not maintain normal values after a Recondition, replace the
battery. See “Replacing the Cache Battery” on page 240.
VessRAID automatically reconditions the battery every two months. To set the
schedule, see “Scheduling an Activity” on page 58.
When you install a new battery, the cycle count shows 0. VessRAID automatically
runs a recondition on the battery to verify it. If you restart the subsystem or
controller before reconditioning is finished, the battery is charged to 100%, then
reconditioning starts again.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...