VessRAID 1000i Series Product Manual
254
RAID 60 – Striping of Double Parity
RAID 60 combines both RAID 6 and RAID 0 features. Data is striped across
disks as in RAID 0, and it uses double distributed parity as in RAID 6. RAID 60
provides data reliability, good overall performance and supports larger volume
sizes.
Figure 8. RAID 60 is a combination of RAID 6 and RAID 0
Figure 9. RAID 60 Striping of Double Distributed Parity disk arrays
The total capacity of a RAID 60 logical drive is the smallest physical drive times
the number of physical drives, minus four.
RAID 60 also provides very high reliability because data is still available even if
multiple physical drives fail (two in each axle). The greater the number of axles,
the greater the number of physical drives that can fail without the RAID 60 logical
drive going offline.
Component
Minimum
Maximum
Number of Axles
2
16
Physical Drives per Axle
4
32
Physical Drives per Logical Drive
8
256
Data
Stripes
Double Distributed Parity
Disk Drives
Axle 1
Axle 2
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...