Chapter 9: Troubleshooting
295
Media patrol is queued
Media patrol has been set manually or by schedule.
Media patrol is stopped
internally
Media patrol stopped because the disk array was
deleted or removed.
Online Capacity Expansion
Online capacity
expansion has started
Result of settings or user action. Normal.
Online capacity
expansion has completed
Normal.
Online capacity
expansion has paused
Expansion paused because of user intervention,
schedule or higher priority background activity.
Online capacity
expansion has resumed
Expansion has resumed again after a pause or a
reboot.
Online capacity
expansion has stopped
Expansion stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Online capacity
expansion has
encountered a physical
disk error
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed. See page 106
(WebPAM PROe) or page 156 (CLU).
Online capacity
expansion is aborted due
to an internal error.
System resources are low. Reduce system load or
restart the VessRAID. See page 94 (WebPAM PROe)
or page 207 (CLU).
Online capacity
expansion is queued
Synchronization has been set manually or by
schedule.
PDM
PDM is started
Result of settings or user action. Normal.
PDM is completed
Normal.
PDM is paused
PDM paused because of user intervention, schedule
or a higher priority background activity.
PDM is resumed
PDM has resumed again after a pause.
PDM is stopped
PDM stopped because of user intervention, schedule
or the logical drive was deleted or went critical or
offline.
PDM is switched to
rebuild.
PDM changed to rebuild because the logical drive
went critical
Reported Event
Corrective Action
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...