VessRAID 1000i Series Product Manual
120
Disk Array Operational Status
•
OK – The normal state of a disk array. For RAID Levels other than RAID 0
(Striping), the disk array has full redundancy.
•
Synchronizing – When you first create a disk array, the disk array
synchronizes. During that time, your data is available. However, access will
be slower until synchronizing is done.
•
Critical/Degraded – This condition results from a physical drive failure. Your
data is still available. However, the disk array has lost redundancy (fault
tolerance). You must determine the cause of the problem and correct it. See
“Critical & Offline Disk Arrays” on page 302.
•
Rebuilding – This condition is temporary. When a physical drive has been
replaced, the disk array automatically begins rebuilding in order to restore
redundancy (fault tolerance). Your data is still available. However, access will
be slower until rebuilding is done.
•
Transport Ready – The result of a successful Prepare for Transport
operation. You remove the physical drives of this disk array and move them
to another enclosure or to different drive slots in the same enclosure. After
you relocate the physical drives, the disk array status will show OK.
Adjustable Items
•
Alias – Optional.
•
Media Patrol – Enabled or disabled.
•
PDM – Enabled or disabled.
See “Making Disk Array Settings” below.
Making Disk Array Settings
To make Disk Array settings:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
Click the Settings tab in Management View.
5.
Optional. Enter an alias in the Disk Array Alias field.
Maximum of 31 characters. Use letters, numbers, space between words,
and underscore. An alias is optional.
6.
To enable Media Patrol support, check the Media Patrol box.
7.
To enable PDM support, check the PDM box.
8.
Click the Submit button.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...