Chapter 8: Technology Background
263
drives. See “Initializing a Logical Drive” on page 129 (WebPAM PROe) or
page 173 (CLU).
Hot Spare Drive(s)
A hot spare is a disk drive that is connected to the disk array system but is not
assigned as a member of the disk array. In the event of the failure of a drive
within a functioning fault tolerant disk array, the hot spare is activated as a
member of the disk array to replace a drive that has failed.
VessRAID will replace a failing disk drive in a disk array with an unassigned drive,
if one is available. The unassigned drive is not part of any disk array. Such a drive
is called a hot spare drive. There are two types:
•
Global – An unassigned disk drive available to any disk array on the
VessRAID.
•
Dedicated – An unassigned disk drive that can only be used by a specified
disk array.
The hot spare policy function lets you choose whether a disk array will access
any unassigned disk drive or a designated drive in the event of disk drive failure.
See “Managing Spare Drives” on page 133 (WebPAM PROe) or page 169 (CLU)
for information on how to make this setting.
The spare drive effectively takes the place of the failed drive and the RAID
system immediately begins to rebuild data onto the drive. When the rebuild is
complete, the disk array is returned to fault tolerant status.
VessRAID includes a function that enables you to return a hot spare drive from a
disk array back to spare status. When you create the hot spare drive, check the
Revertible box to enable this feature. See “Transition” on page 273.
See also “Critical & Offline Disk Arrays” on page 302.
Partition and Format the Logical Drive
Like any other type of fixed disk media in your system, a RAID logical drive must
also be partitioned and formatted before use. Use the same method of
partitioning and formatting on an logical drive as you would any other fixed disk.
Depending on the operating system you use, there may or may not be various
capacity limitations applicable for the different types of partitions.
Caution
When you initialize a logical drive, all the data on the logical drive
will be lost. Backup any important data before you initialize a
logical drive.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...