DA95F (WF96) - Printer Parts Removal
Blue Piece on
Main Board
Connector
Black Tab at End of
Cable is Facing Down
5.36 Print
Head Cables
and Print
Head Boards
(continued)
Location
on Main
Board
Description
Comments
J1
Print Head 1
Bank (Set)
A
J2
Print Head 2
J3
Print Head 3
J4
Print Head 4
Bank (Set)
B
J5
Print Head 5
J6
Print Head 6
J1 J2 J3
J1 J2 J3
J4 J5 J6
J4 J5 J6
Main Board Showing all Six Print Head Cable Connections
22. On other side of chassis wall to which the main board is mounted, route
cables through the wire management device (plastic clips) and allow
enough slack on cables for print head to travel to opposite side of printer.
Slack in Print Head Cables (Circled)
Wire Management Device
for Print Head Cables
21. Attach print head cables to main board connectors (see figures below).
Apply a light push to the cable while inserting to allow it to seat fully and
straight into the connector socket. Make sure the cable end is marked
"MMC" for main board and the black tab at the cable end is facing down
as it is being inserted into the print head connector. After inserting cable,
press down on blue connector piece to lock cable into place.
CAUTION:
Partial or crooked insertion of print head cable can result in
main board, print head board, and/or cable damage!