4/4
G 1000
Alcatel Vacuum Technology France - ATH 200 User’s Manual
GB 04070- Edition 03 - Jan. 12
Hand held remote - Set up menu
Selection
Setting limits
Initial
confi guration
ACCESS CODE
0 to 65535
0
Enter the access code and validate
REMOTE CONTROL
Keyboard/Remote hard/Serial link/Profi bus/
DeviceNet
Profi bus
Select the remote mode
STANDBY SPEED
15000 to nominal speed of the connected
pump
15000
Modify the standby speed from 15000
to nominal speed
BUZZER
ON /OFF
OFF
Activate or deactivate the buzzer.
THERMOSTAT
ON = adjustable temp. from 30 to 75°C
OFF
OFF
Regulate the pump temperature
RELAY AT SPEED
- 3 to - 50%
- 3
Modify the speed contact threshold.
FIELDBUS PROFILE (1)
0 or 1 (only for Profi bus)
0
0 compatible with OBCV4
1 compatible with OBCV3
FIELDBUS ADDRESS
Profi bus : MSB and LSD
DeviceNet: ID and Data Rate
XX and YY
Display the Profi
bus address or
DeviceNet address, data rate
RS 232 SPEED
9K6 - 19K2 / 38K4 / 57K6
9K6
Modify the RS 232 speed.
RS 232 ECHO
ON / OFF
OFF
Authorize or not authorize the echo of
characters received on the link
RS 232 SEPARATOR
0-255
44
Data separating chararcter (044 =
comma).
RS 232 ADDRESS
0-255
0
Number of controller in a multiple link.
BEARING LIFE
Warning limit
0 to 99%
20
Modify the bearing alert threshold.
NEW CODING
0 to 65535
0
Modify the access code.
DISPL AY
S E T U P
S E R N U M
E N T E R
* see Pump User’s manual.
-
+
Selection
Initial confi guration
HHR
XXXXXXXXXX
Display the HHR serial number
CONTROLLER
YYYYYYYYYY
Display the front panel serial number
CARTRIDGE (2)
ZZZZZZZZZZ
Display the spindle serial number
MMCC06 (2)
AAAAAAAAA
Display the electronical board serial number
D I S P L AY
S E T U P
S E R N U M
E N T E R
-
+
(1) When the HHR is connected to an OBC controller (2) When the HHR is connected to an ATH 500 pump
adixen Vacuum Products - Operating instructions - ATH 500 M-MT
adixen Vacuum Products - Operating instructions - ATH 500 M-MT