4/5
B 300
Pump connections to an installation
GB 03367 - Edition 03 - Jan. 12
10
9
8
7
6
5
4
3
2
1
0
20
40
60
80
100
120
0
0
0.5
1
1.5
2
2.5
Loads transmitted to the
system (cont.)
Pump model
Unit
ATH 500 M-MT
Nominal speed
rpm
50 000
Energy
kNm
24
Torque
Max. KNm
9
Duration ms
1
Delay ms
1
Bending moment
Max. KNm
6
Duration ms
0.5
Delay ms
0
Axial force *
Max. KN
0 to 110
Duration ms
0.3
Delay ms
0
* Max. axial force occurs if the pump inlet is obstructed with high stiffness
parts. There is no load if the system has low stiffness (i.e. valve).
ATH 500 M-MT
Estimated transmitted forces
Torque - Bending moment - K N.m
Axial Force - K N
Torque
Bending moment
Axial force
Time - ms
adixen Vacuum Products - Operating instructions - ATH 500 M-MT