Pump electrical
connection
1 - Identify the main index on the male connector of the pump.
A: po of 48 VDC
B : polarity - of 48 VDC
C : Potential Earth
D : Not connected
2 - Identify the main index on the female
connector of the power supply’s cable.
Index
A
B
C
Index
D
3 - Insert the female connector in
accordance to the main index, then rotate
the ring until locked
48 VDC
cable plug*
*Plug : provided by the customer.
Ref. UTS6JC1045 - Supplier : Souriau - France
4 - If the pump is equipped with a fan, supply it in 48VDC. The
external power supply (accessory) allows to power the fan.
6 - If the pump is equipped with a purge valve, connect the valve to
the 24 VDC power supply (customer supplied).
ATH 500M
only
5 - Check that the heater band and the water valve are both
supplied (connected on ‘HEATER’ and ‘VALVE’ electronic front
panel).
ATH 500MT
uniquement
Red cable eyes : fan
power supply.
Blue cable eyes : pump
power supply.
48 VDC external power supply
(accessory)
Pump power supply
Fan power supply
Power line
GB 03370 - Edition 03 - Jan 12
3/4
B 400
Safety instructions and electrical
connections
adixen Vacuum Products - Operating instructions - ATH 500 M-MT
adixen Vacuum Products - Operating instructions - ATH 500 M-MT