Touch Screens
7-28
Diagnostics
This button displays the diagnostic dialog, used to make sure that
your instrument and its accessories have been installed properly and
are functioning properly.
Recommended
Conditions
This button displays the Recommended Conditions dialog, which
shows recommended analytical conditions for determining the active
element.
The data tab displays the recommended setup and diagnostic
parameters of wavelength, slit width, relative noise, characteristic
concentration, sensitivity check, and linear to mg/L.
The remark tab displays special conditions about the element that
you are determining.
To view a different element for recommended conditions, the
element in lamp page must be changed.
Network
This button displays the Network dialog, that is use to setup a
network connection between the instrument and a stand-alone or a
network computer. Once a network connection is established, all the
analyses result data will automatically be saved.
Calibrate Stylus
Touch this button to run a system utility to recalibrate the touch
screen if the screens are not responding properly to your touch.
Print Method
Touch this button to print the current active method.
Service
This button is to be used by service engineers.
Download
This button is to be used to upgrade software.
Set Date and Time
Touch this button to set time zone, daylight saving, date, and time.
Regional Setting
Touch this button to format date and time display.
Startup
Touch this button to change technique.
Optical position
Touch this button to show a plot of the most recent wavelength
peaking operation for diagnostic purposes.
Summary of Contents for aanalyst 200
Page 1: ...AAnalyst 200 User s Guide ...
Page 6: ......
Page 7: ...Introduction 1 ...
Page 8: ......
Page 18: ...Introduction 1 12 ...
Page 19: ...Safety Practices 2 ...
Page 20: ......
Page 44: ...Safety Practices 2 26 ...
Page 45: ...Preparing Your Lab 3 ...
Page 46: ......
Page 66: ...Preparing Your Lab 3 22 ...
Page 67: ...System Description 4 ...
Page 68: ......
Page 89: ...Installation 5 ...
Page 90: ......
Page 115: ...Operation of the Instrument 6 ...
Page 116: ......
Page 132: ...Operation of the Instrument 6 18 Figure 6 9 Installing the lamp compartment cover ...
Page 158: ...Operation of the Instrument 6 44 ...
Page 159: ...Touch Screens 7 ...
Page 160: ......
Page 173: ...AAnalyst 200 User s Guide 7 15 Screen 7 10 Spectrometer Subpage Flame Technique ...
Page 210: ...Touch Screens 7 52 ...
Page 211: ...Analyzing Samples 8 ...
Page 212: ......
Page 220: ...Analyzing Samples 8 10 Screen 8 4 Display Calibration screen ...
Page 231: ...AAnalyst 200 User s Guide 8 21 The results are displayed and printed Screen 8 12 Analyze page ...
Page 244: ...Analyzing Samples 8 34 ...
Page 245: ...Maintenance 9 ...
Page 246: ......
Page 268: ...Maintenance 9 24 Figure 9 6 Removing the burner assembly from the instrument ...
Page 291: ...AAnalyst 200 User s Guide 9 47 Figure 9 15 Removing the E Box from the instrument ...
Page 293: ...AAnalyst 200 User s Guide 9 49 Figure 9 16 Replacing the E Box ...
Page 307: ...Troubleshooting 10 ...
Page 308: ......
Page 320: ...Troubleshooting 10 14 ...
Page 321: ...Index ...
Page 322: ......