Parker Hannifin
P Series User Guide
66
NOTE) When using PC as host controller, USB to RS-422 communication convertor is
required.
4.2.1 Terminal Configuration
Item
Specifications
Communication Standard
ANSI/TIA/EIA-422 Standard
Communication Protocol
MODBUS-RTU
Connector
RJ45 x 2
Data
Type
Data bit
8bit
Stop bit
1bit
Parity
None
Synchronism
Asynchronous method
Transmission Speed
9600 /19200/38400/57600 [bps]
Speed can be selected at communication speed setting
[0x3002]
Transmission Distance
Up to 200 [m]
Power Consumption
Under 100[
㎃
]
Table 20. RS-422 Terminal Specification
4.2.2
Establishing Communication
The terminating resistance used for RS-422 communication is configured within this
drive.
The terminating resistance inside the drive is 120Ω. To use the terminating resistance,
turn on the switch as shown in the figure below.
www.comoso.com
Summary of Contents for P Series
Page 16: ...Parker Hannifin P Series User Guide Change Summary www comoso com...
Page 60: ...Parker Hannifin P Series User Guide 58 3 11 3 I O Signal Wiring www comoso com...
Page 292: ...Parker Hannifin P Series User Guide 290 www comoso com...
Page 293: ...Parker Hannifin P Series User Guide 291 Figure 60 FCL Series N T Curves www comoso com...
Page 294: ...Parker Hannifin P Series User Guide 292 10 5 FE Series N T Curves www comoso com...
Page 295: ...Parker Hannifin P Series User Guide 293 www comoso com...
Page 296: ...Parker Hannifin P Series User Guide 294 www comoso com...
Page 297: ...Parker Hannifin P Series User Guide 295 www comoso com...
Page 298: ...Parker Hannifin P Series User Guide 296 www comoso com...
Page 300: ...Parker Hannifin P Series User Guide 298 www comoso com...
Page 301: ...Parker Hannifin P Series User Guide 299 Figure 62 FF Series N T Curves www comoso com...