Parker Hannifin
P Series User Guide
159
6.9.2 Signals Related with Position Control
As shown in the figure below, the difference between the position command value from the
host controller and the position feedback value, that is the position error, is under the
INPOS1 output range (0x2401) and is maintained for the duration of INPOS1 output
time(0x2402), the INPOS1(In Position 1) signal is displayed. However, the INPOS1 signal is
displayed only when the position command is not updated.
In addition, regardless whether the position command is updated, the INPOS2 (In Position 2)
signal is displayed when the position error is below the INPOS2 output range (0x2403).
Related Objects
Index
Sub
Index
Name
Variable
Format
Accessibility
PDO
Allocation
Unit
0x2401
-
INPOS1 Output Range
UINT
RW
Yes
UU
0x2402
-
INPOS1 Output Time
UINT
RW
Yes
ms
0x2403
-
INPOS2 Output Range
UINT
RW
Yes
UU
Table 84. Position Control Related Objects
(In case of output time =
www.comoso.com
Summary of Contents for P Series
Page 16: ...Parker Hannifin P Series User Guide Change Summary www comoso com...
Page 60: ...Parker Hannifin P Series User Guide 58 3 11 3 I O Signal Wiring www comoso com...
Page 292: ...Parker Hannifin P Series User Guide 290 www comoso com...
Page 293: ...Parker Hannifin P Series User Guide 291 Figure 60 FCL Series N T Curves www comoso com...
Page 294: ...Parker Hannifin P Series User Guide 292 10 5 FE Series N T Curves www comoso com...
Page 295: ...Parker Hannifin P Series User Guide 293 www comoso com...
Page 296: ...Parker Hannifin P Series User Guide 294 www comoso com...
Page 297: ...Parker Hannifin P Series User Guide 295 www comoso com...
Page 298: ...Parker Hannifin P Series User Guide 296 www comoso com...
Page 300: ...Parker Hannifin P Series User Guide 298 www comoso com...
Page 301: ...Parker Hannifin P Series User Guide 299 Figure 62 FF Series N T Curves www comoso com...