Electronic gears are generally used for the following purposes.
When driving loads based on the user unit.
-
You can give command based on the user unit, regardless of the encoder (motor) type.
The table below shows comparison between 5000ppr encoder and 19bit encoder, when
moving 12mm using the same 10mm-pitch ball screw.
(A) 5000ppr Encoder
(B) 19bit (524288 ppr)
Encoder
Without
electronic gear
5000*12/10 = 6000
524288*12/10=629145.6
Different commands should be given to each encoder (motor) when
moving the same distance
When giving command based on the minimum unit (user unit) of 1um(0.001mm)
Electronic gear
setting
Motor Revolutions =5000
Shaft Revolutions = 10000
Motor Revolutions =524288
Shaft Revolutions = 10000
With electronic
gear
You can give the same command to move 12000(12mm=
12000*1um) regardless of the encoder (motor) type.
www.comoso.com
Summary of Contents for P Series
Page 16: ...Parker Hannifin P Series User Guide Change Summary www comoso com...
Page 60: ...Parker Hannifin P Series User Guide 58 3 11 3 I O Signal Wiring www comoso com...
Page 292: ...Parker Hannifin P Series User Guide 290 www comoso com...
Page 293: ...Parker Hannifin P Series User Guide 291 Figure 60 FCL Series N T Curves www comoso com...
Page 294: ...Parker Hannifin P Series User Guide 292 10 5 FE Series N T Curves www comoso com...
Page 295: ...Parker Hannifin P Series User Guide 293 www comoso com...
Page 296: ...Parker Hannifin P Series User Guide 294 www comoso com...
Page 297: ...Parker Hannifin P Series User Guide 295 www comoso com...
Page 298: ...Parker Hannifin P Series User Guide 296 www comoso com...
Page 300: ...Parker Hannifin P Series User Guide 298 www comoso com...
Page 301: ...Parker Hannifin P Series User Guide 299 Figure 62 FF Series N T Curves www comoso com...