Parker Hannifin
P Series User Guide
123
Speed loop integral time
constant 1(x2103)
Torque command filter time
constant 1(0x2104)
time1(0x211C)
Gain conversion time
2(0x211B)
Gain conversion waiting
time2(0x211D)
Speed loop integral time
constant 2(x2107)
Torque command filter time
constant 2(0x2108)
5.10.2
Related Objects
Index
Sub
Index
Name
Variable
Format
Accessibility
PDO
Allocation
Unit
0x2119
-
Gain Conversion Mode
UINT
RW
Yes
-
0x211A
-
Gain Conversion Time 1
UINT
RW
Yes
ms
0x211B
-
Gain Conversion Time 2
UINT
RW
Yes
ms
0x211C
-
Gain Conversion Waiting Time 1
UINT
RW
Yes
ms
0x211D
-
Gain Conversion Waiting Time 2
UINT
RW
Yes
ms
Table 70. Gain Conversion Related Objects
5.10.3 P/PI Control Conversion
PI control uses both proportion (P) gain and integral (I) gain of the speed controller.
P control refers to control using only proportion gain.
Proportion gain determines the response of the overall controller, and the integral
gain is used to remove the error of the steady state. Excessive integral gain leads to
overshoot during acceleration/deceleration.
www.comoso.com
Summary of Contents for P Series
Page 16: ...Parker Hannifin P Series User Guide Change Summary www comoso com...
Page 60: ...Parker Hannifin P Series User Guide 58 3 11 3 I O Signal Wiring www comoso com...
Page 292: ...Parker Hannifin P Series User Guide 290 www comoso com...
Page 293: ...Parker Hannifin P Series User Guide 291 Figure 60 FCL Series N T Curves www comoso com...
Page 294: ...Parker Hannifin P Series User Guide 292 10 5 FE Series N T Curves www comoso com...
Page 295: ...Parker Hannifin P Series User Guide 293 www comoso com...
Page 296: ...Parker Hannifin P Series User Guide 294 www comoso com...
Page 297: ...Parker Hannifin P Series User Guide 295 www comoso com...
Page 298: ...Parker Hannifin P Series User Guide 296 www comoso com...
Page 300: ...Parker Hannifin P Series User Guide 298 www comoso com...
Page 301: ...Parker Hannifin P Series User Guide 299 Figure 62 FF Series N T Curves www comoso com...