Parker Hannifin
P Series User Guide
192
By combining the Wait for Start signal and the Next Index signal, a bifurcation
structure shown in the figure below can be constructed.
To do this, the action of the index 3 should be set to Wait for Start.
8.2.2 Absolute and Relative Move
This is the most basic Point-to-Point (PTP) operation method where the motor rotates to the
absolute or relative position based on the set speed and acceleration.
Absolute Move
The final distance is the difference between the distance and the current position.
Example) Absolute move when current position = 500 and Distance = 1000
Relative Move
The final distance is the input value of the distance.
Example) Relative move when current position = 500 and Distance = 1000
time
www.comoso.com
Summary of Contents for P Series
Page 16: ...Parker Hannifin P Series User Guide Change Summary www comoso com...
Page 60: ...Parker Hannifin P Series User Guide 58 3 11 3 I O Signal Wiring www comoso com...
Page 292: ...Parker Hannifin P Series User Guide 290 www comoso com...
Page 293: ...Parker Hannifin P Series User Guide 291 Figure 60 FCL Series N T Curves www comoso com...
Page 294: ...Parker Hannifin P Series User Guide 292 10 5 FE Series N T Curves www comoso com...
Page 295: ...Parker Hannifin P Series User Guide 293 www comoso com...
Page 296: ...Parker Hannifin P Series User Guide 294 www comoso com...
Page 297: ...Parker Hannifin P Series User Guide 295 www comoso com...
Page 298: ...Parker Hannifin P Series User Guide 296 www comoso com...
Page 300: ...Parker Hannifin P Series User Guide 298 www comoso com...
Page 301: ...Parker Hannifin P Series User Guide 299 Figure 62 FF Series N T Curves www comoso com...