Parker EME
Compax3 Accessories
192-120101 N11 C3I11T11 November 2007
253
9.2
EMC measures
In this chapter you can read about:
Mains filter .......................................................................................................................................253
Motor output filter.............................................................................................................................257
Mains filter .......................................................................................................................................258
9.2.1.
Mains filter
For radio disturbance suppression and for complying with the emission limit values
for
CE conform operation
(see page 15)we offer mains filters:
Observe the maximum permitted length of the connection between the mains filter
and the device:
unshielded <0.5m;
shielded < 5m (fully shielded on ground – e.g. ground of control cabinet)
Order code mains filter Compax3S / Compax3H
/
for C3S025V2 or S063V2
NFI
0 1 / 0
1
for C3S0xxV4, S150V4 or S1xxV2
NFI
0 1 / 0
2
for C3S300V4
NFI
0 1 / 0
3
for C3H050V4
NFI
0 2 / 0
1
for C3H090V4
NFI
0 2 / 0
2
for C3H1xxV4
NFI
0 2 / 0
3
Order code mains filter Compax3MP
/
for C3MP10
Reference axis combination 3x480V 25A
6x10m motor cable length
NFI
0 3 / 0
1
for C3MP10
Reference axis combination 3x480V 25A
6x50m motor cable length
NFI
0 3 / 0
2
9.2.1.1
Mains filter NFI01/01
for Compax3 S025 V2 and Compax3 S063 V2
Dimensional drawing:
50,8±0,3
85,4
116
139
7
9
,5
1
0
1
8
8
,9
±
0
,4
5
5
,5
Ø 4
5,2 x 4
L
I
N
E
L
O
A
D