Setting
up Compax3
Positioning via digital I/Os
204
192-120101 N11 C3I11T11 November 2007
4.4.9.6
Measurement of frequency responses
In this chapter you can read about:
Safety instructions concerning the frequency response measurement ...........................................204
Functionality of the measurement....................................................................................................204
Open/Closed Loop frequency response measurement ...................................................................206
Excitation Signal ..............................................................................................................................207
Non-linearities and their effects .......................................................................................................208
Please note that you require a
licence hey
(see page 196, see page 194) for
this application!
Safety instructions concerning the frequency response measurement
During the measurement of the frequency response, the control is changed and
influenced in multiple ways. You should therefore respect the following notes:
During the measurement, the entire system is excited via a broad frequency
spectrum. This might damage especially sensitive components (such as lenses)
The risk increases with the extent of the excitation. In addition, natural
mechanical frequencies may cause an increased excitation of individual
components.
The measurement of the frequency response can only be made in the setup
mode with energized controller.
During the current measurement (between start and stop of the measurement),
no write flash may be executed.
In the event of a break in communication during the measurement, the controller
must be switched off and then on again in order to reestablish the original status.
Changes of the controller parameters during the measurement are not permitted.
Those may be overwritten by standard values when the measurement is
terminated.
Functionality of the measurement
Basic structure of a frequency response measurement
System S
G(S)
Input
Eingangs