Setting
up Compax3
Positioning via digital I/Os
106
192-120101 N11 C3I11T11 November 2007
In order to be able to position according to the specified positioning data records, it
is usually necessary to carry out a machine zero run after switching on (if machine
zero has been configured). This takes place automatically with the first START
after Power On. For this purpose the machine zero proximity switch must be
connected to X12/14.
When sequential positioning mode has been chosen the first positioning takes
place in response to a START signal (X12/7=24VDC).
In single positioning mode the desired positioning data record is selected via the
digital inputs I3-I7(I6) (
Stecker X12
(see page 58)) and activated via a START
signal (X12/7=24VDC)
Positioning