Compax3
device description
Positioning via digital I/Os
40
192-120101 N11 C3I11T11 November 2007
Mains connection Compax3MP10D6
Device type Compax3
MP10
Supply voltage
Rated voltage 3AC 400V
230-480VAC ±10% / 50-60Hz
Input current
22Aeff
Maximum fuse rating per device
(=short circuit rating)
25A
MTP miniature circuit breaker (ABB)
Recommendation: S203-K25
The Compax3MP10D6 devices must only be operated with three phases!
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
3.4.7.
Braking resistor / temperature switch Compax3MP (mains
module)
The energy generated during braking operation must be dissipated via a braking
resistor.
Connector X40
PIN
Description
+R
+ Braking resistor
-R
- Braking resistor
no short-circuit
protection!
PE PE
T1R Temperature
Switch
T2R Temperature
Switch
Braking operation Compax3MP10D6 (mains module)
Device type Compax3
MP10
Capacitance / storable energy
550µF/
92Ws at 400V
53Ws at 480V
Minimum braking- resistance
27
Ω
Recommended nominal power rating
500 ... 1500W
Pulse power rating for 1s
22kW
Maximum permissible continuous current
13A
Braking operation Compax3MxxxD6 (axis controller)
Device type Compax3
M050
M100
M150
Capacitance / storable energy
110µF/
18Ws at 400V
10Ws at 480V
220µF/
37Ws at 400V
21Ws at 480V
220µF/
37Ws at 400V
21Ws at 480V
Caution!