Parker EME
Technical data
192-120101 N11 C3I11T11 November 2007
295
Mains connection Compax3S0xxV2 1AC
Controller type
S025V2
S063V2
Supply voltage
Single phase 230VAC/240VAC
80-253 VAC/50-60Hz
Input current
6Aeff 13Aeff
Maximum fuse rating per device
(=short circuit rating)
10 A (circuit breaker
K)
16 A (circuit breaker K)
Mains connection Compax3S1xxV2 3AC
Controller type
S100V2
S150V2
Supply voltage
Three phase 3* 230VAC/240VAC
80-253 VAC/50-60Hz
Input current
10Aeff
13Aeff
Maximum fuse rating per device
(=short circuit rating)
16 A (circuit breaker
K)
20 A (circuit breaker K)
Mains connection Compax3SxxxV4 3AC
Controller type
S015V4
S038V4
S075V4
S150V4
S300V4
Supply voltage
Three phase 3*400VAC/480VAC
80-528VAC / 50-60Hz
Input current
3Aeff 6Aeff 10Aeff
16Aeff
22Aeff
6A 10A 16A 20A
25A
Maximum fuse rating per
device(=short circuit
rating)
MTP miniature circuit breaker
D*
* for
UL conform operation
(see page 18): MTP miniature circuit breaker S273-K.
Mains connection Compax3MP10D6
Device type Compax3
MP10
Supply voltage
Rated voltage 3AC 400V
230-480VAC ±10% / 50-60Hz
Input current
22Aeff
Maximum fuse rating per device
(=short circuit rating)
25A
MTP miniature circuit breaker (ABB)
Recommendation: S203-K25
Mains connection Compax3HxxxV4
Controller type
H050V4
H090V4
H125V4
H155V4
Supply voltage
Three phase 3*400VAC/480VAC
350-528VAC / 50-60Hz
Input current
54Aeff
93Aeff
118Aeff
140Aeff
60A 100A
125A
150A
Maximum fuse rating per
device(=short circuit
rating)
JDDZ class K5,
JDRX class H
JDDZ class H5,
JDRX class H
10. Technical data