Parker EME
Setting up Compax3
192-120101 N11 C3I11T11 November 2007
87
MN-M 3.4: MN-Initiator = 1 on the positive side
The MN initiator can be positioned at any location within the travel range. The
travel range is then divided into 2 contiguous ranges: one range with deactivated
MN initiator (left of the MN initiator) and one range with activated MN initiator (right
of the MN initiator).
When the MN initiator is inactive (signal = 0) the search for the machine reference
is in the positive travel direction.
MN-M 3:
The 1st motor zero point with MN initiator = "1" is used as MN.
MN-M 4:
The 1st motor zero point with MN initiator = "1" is used as MN.
3
4
4
3
1
2
1: Motor zero point
2: Logic state of the home switch
MN-M 5.6: MN initiator = 1 on the negative side
The MN initiator can be positioned at any location within the travel range. The
travel range is then divided into 2 contiguous ranges: one range with deactivated
MN initiator (positive part of the travel range) and one range with activated MN
initiator (negative part of the travel range).
When the MN initiator is inactive (signal = 0) the search for the machine reference
is in the negative travel direction.
MN-M 5:
The 1st motor zero point with MN proximity switch = "0" is used as MN.
MN-M 6:
The 1st motor zero point with MN initiator = "1" is used as MN.
6
5
5
6
1
2
1: Motor zero point
2: Logic state of the home switch
With motor zero
point, without
direction reversal
switches
With motor zero
point, without
direction reversal
switches