Setting
up Compax3
Positioning via digital I/Os
94
192-120101 N11 C3I11T11 November 2007
START:
I1: START signal
POS:
O1: Position reached
Sequence:
PLC
Reaction Compax3
START of a positioning
Position reached goes to "0"
From position reached = "0" follows:
START = 0
Positioning completed
Position reached =
"1"
From position reached = "1" follows:
Next START can take place
Position reached goes to "0"
Handshake with PLC
for small
positionings