Parker EME
Compax3 device description
192-120101 N11 C3I11T11 November 2007
29
Power supply plug X1 for 3AC 230VAC/240VAC devices
PIN
Designation
1 L1
2 L2
3 L3
4 PE
Mains connection Compax3S1xxV2 3AC
Controller type
S100V2
S150V2
Supply voltage
Three phase 3* 230VAC/240VAC
80-253 VAC/50-60Hz
Input current
10Aeff
13Aeff
Maximum fuse rating per device
(=short circuit rating)
16 A (circuit breaker
K)
20 A (circuit breaker K)
The 3AC V2 – devices must only be operated with three phases!
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
3.3.5.2
Braking resistor / high voltage DC C3S connector X2
In this chapter you can read about:
Braking resistor / high voltage supply plug X2 for 1AC 230VAC/240VAC devices............................29
Braking resistor / high voltage supply plug X2 for 3AC 230VAC/240VAC devices............................30
Connection of a braking resistor ........................................................................................................30
The energy generated during braking operation is absorbed by the Compax3
storage capacity.
If this capacity is too small, the braking energy must be drained via a braking
resistor.
Braking resistor / high voltage supply plug X2 for 1AC
230VAC/240VAC devices
PIN
Designation
1 Reserved
2
- braking resistor (not short-circuit protected!)
3 PE
4
+ braking resistor (not short-circuit protected!)
5 Reserved
Braking operation Compax3S0xxV2 1AC
Controller type
S025V2
S063V2
Capacitance / storable energy
560
μ
F / 15Ws
1120
μ
F / 30Ws
Minimum braking- resistance
100
Ω
56
Ω
Recommended nominal power rating
20 ... 60W
60 ... 180W
Maximum continuous current
8A 15A
Caution!