Technical
data
Positioning via digital I/Os
308
192-120101 N11 C3I11T11 November 2007
COM ports
RS232
115200 baud
Word length: 8 bits, 1 start bit, 1 stop bit
Hardware handshake XON, XOFF
RS485 (2 or 4-wire)
9600, 19200, 38400, 57600 or 115200
baud
Word length 7/8 bit, 1 start bit, 1 stop bit
Parity (can be switched off) even/odd
2 or 4-wire
USB (Compax3M)
USB 2.0 Full Speed compatible
Functions
Positioning
up to 31 positioning data records possible
with the following settings.
Target position
Velocity
Acceleration
Deceleration
Repeat count
Jerk specification
Sequential or single positioning
Different machine zero modes
Absolute / continuous operation
Normal / setup mode
Actual position
Encoder Simulation
Resolution: 4 - 16384 Increments /
revolution
Signal monitor
2 channels ±10 V analog
Resolution: 8 Bit
8 digital inputs (24V level)
Energize motor, Stop, Start, Quit,
up to 5 addresses for positioning data
record selection, home sensor, Jog+,
Jog-.
4 digital outputs
Error, position reached, power output
stage without corrent, motor stationary
with setpoint 0.
Loading max. 100mA