![Parker Compax3S025V2 Operating Instructions Manual Download Page 36](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775036.webp)
Compax3
device description
Positioning via digital I/Os
36
192-120101 N11 C3I11T11 November 2007
3.4.3.
Connections of the axis combination
The Compax3M axis controllers are connected to the supply voltages via rails.
Supply voltage 24VDC
DC power voltage supply
The rails can be found behind the yellow protective covers. In order to connect the
rails of the devices, you may have to remove the yellow plastic device inserted at
the side.
Protective covers
In order to secure the contact protection against the alive rails, it is absolutely
necessary to respect the following:
Insert the yellow plastic device at the left or right of the rails.
Make sure that the yellow plastic device is placed at the left of the first device and
at the right of the last device in the combination and have not been removed.
Setup of the devices only with closed protective covers.
1 24VDC
2
Gnd 24 V
3 -HV
DC
4 PE
5 +HV
DC
Note:
External components
may not
be connected to the rail system.
Protective covers
The user is responsible for protective covers and/or additional safety measures in order to
prevent damages to persons and electric accidents.