![Parker Compax3S025V2 Operating Instructions Manual Download Page 300](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775300.webp)
Technical
data
Positioning via digital I/Os
300
192-120101 N11 C3I11T11 November 2007
Resulting nominal and peak currents depending on the switching
frequency
Compax3MxxxD6 at 3*400VAC
Switching
frequency*
M050D6 M100D6 M150D6
I
nominal
5A
eff
10A
eff
15A
eff
8 kHz
I
peak
(<5s)
10A
eff
20A
eff
30A
eff
I
nominal
3.8A
eff
7.5A
eff
10A
eff
16kHz
I
peak
(<5s)
7.5A
eff
15A
eff
20A
eff
I
nominal
2.5A
eff
3.8A
eff
5A
eff
32kHz
I
peak
(<5s)
5A
eff
7.5A
eff
10A
eff
Compax3MxxxD6 at 3*480VAC
Switching
frequency*
M050D6 M100D6 M150D6
I
nominal
4A
eff
8A
eff
12.5A
eff
8 kHz
I
peak
(<5s)
8A
eff
16A
eff
25A
eff
I
nominal
3A
eff
5.5A
eff
8A
eff
16kHz
I
peak
(<5s)
6A
eff
11A
eff
16A
eff
I
nominal
2A
eff
2.5A
eff
4A
eff
32kHz
I
peak
(<5s)
4A
eff
5A
eff
8A
eff
The values marked with grey are the pre-set values (standard values)!
*corresponds to the frequency of the motor current