Parker EME
Compax3 device description
192-120101 N11 C3I11T11 November 2007
57
Note on F12:
*+5V (Pin 4) is measured and controlled directly at the end of the line via Sense –
and Sense +.
Maximum cable length: 100m
Pin 4 and Pin 5 must under no circumstances be connected!
Plug in or pull out feedback connector only in switched off state (24VDC switched
off).
3.7.2.
Analog / Encoder (plug X11)
PIN X11 Reference
High Density Sub D
1
+24V (output for encoder) max. 70mA
2
Ain1 -: analog input - (14Bit; max. +/-10V)
3
D/A monitor channel 1 (±10V, 8-bit resolution)
4
D/A monitor channel 0 (±10V, 8-bit resolution)
5
+5V (output for encoder) max. 150mA
6
A/
(Encoder simulation)
7
A
(Encoder simulation)
8
B
(Encoder simulation)
9
Ain0 +: analog input + (14Bit; max. +/-10V)
10
Ain1 +: analog input + (14Bit; max. +/-10V)
11
Ain0 -: analog input - (14Bit; max. +/-10V)
12
B/
(Encoder simulation)
13
N/
(encoder simulation)
14
N
(encoder simulation)
15 GND
3.7.2.1
Wiring of analog interfaces
Output
Input
+/-10V/1mA
(max: 3mA)
X11/3
X11/15
332W
X11/4
Com
pax
3
10nF
2.2KW
10KW
Ain+
2.2KW
X11/9
10KW
10nF
Ain-
X11/11
2.5V
Com
pax
3
Please note: with Ain- on earth and Ain+ open,
2.02V are read in.
Caution!