9.2.2.
Motor output filter
In this chapter you can read about:
Motor output filter MDR01/04...........................................................................................................257
Motor output filter MDR01/01...........................................................................................................257
Motor output filter MDR01/02...........................................................................................................258
Wiring of the motor output filter........................................................................................................258
We offer motor output filters for disturbance suppression when the motor
connecting cables are long (>20m):
Order code for motor output filter (for Compax3S, Compx3M >20m motor cable)
/
up to 6,3 A rated motor current
MDR
0 1 / 0
4
Up to 16 A rated motor current
MDR
0 1 / 0
1
up to 30 A rated motor current
MDR
0 1 / 0
2
9.2.2.1
Motor output filter MDR01/04
up to 6.3A nominal motor current (3.6mH)
Dimensional drawing:
120
54
95
5
90
40
1
7
0
U1 V1
W1
+
-
U2 V2
W2
+
-
9.2.2.2
Motor output filter MDR01/01
Up to 16 A nominal motor current (2mH)
Dimensional drawing:
150
67
95
6
113
50
1
9
5
U1 V1
W1
+
-
U2 V2
W2
+
-