A d m i n i s t r a t i o n
3-7
3
Continue with other SNMP settings, or press Escape to return to the Main
menu.
4
Reset the IAD.
Enable/Disable SNMP via EOC
To Enable or Disable SNMP via EOC, follow the steps below.
1
Type
“F”
on the SNMP Configuration menu to enable or disable SNMP via
EOC. The IAD displays the current status of SNMP.
2
To enable SNMP, type
“E”
or type
“D”
to disable. The IAD saves the
configuration (if changed).
3
Continue with other SNMP settings, or press Escape to return to the Main
menu.
4
Reset the IAD.
Enable SNMP via Both IP and EOC
To Enable SNMP via Both IP and EOC, follow the steps below.
1
Type
“A”
on the SNMP Configuration menu to enable SNMP via IP and
EOC. The IAD saves the configuration.
2
Continue with other SNMP settings, or press Escape to return to the Main
menu.
3
Reset the IAD.
Disable SNMP via Both IP and EOC
To Disable SNMP via both IP and EOC, follow the steps below.
1
Type
“B”
on the SNMP configuration menu to disable SNMP via IP and
EOC. The IAD saves the configuration.
2
Continue with other SNMP settings, or press Escape to return to the Main
menu.
3
Reset the IAD.
Configure System Contact
To configure the System Contact, follow the steps below.
1
Type
“P”
on the SNMP Configuration menu to configure system contact
(up to 39 alphanumeric characters). The IAD displays the current system
contact and prompts you to enter a new one.
2
Type the name of the new contact person or department and press Enter.
The IAD save the configuration.
3
Continue with other SNMP settings, or press Escape to return to the Main
menu.
4
Reset the IAD.
Summary of Contents for JetFusion 2208
Page 6: ...E 2 0 0 0 A 2 G B 2 1 1 0...
Page 22: ...1 6 2 0 0 0 A 2 G B 2 1 1 0...
Page 198: ...6 12 2 0 0 0 A 2 G B 2 1 1 0...
Page 206: ...7 8 2 0 0 0 A 2 G B 2 1 1 0...
Page 210: ...8 4 2 0 0 0 A 2 G B 2 1 1 0...
Page 212: ...A 2 2 0 0 0 A 2 G B 2 1 1 0...
Page 224: ...B 12 2 0 0 0 A 2 G B 2 1 1 0...