3-113
Note
Related page
・
A parameter is designated as follows:
Pr0.00
No.
Class
・
For
“ Attribute ”,refer to P.3-38
“ Details of Attribute ”.
・
P.2-47
〜
“
Wiring to the Connector
,
X4
”
Default: [ ]
Rev.2.00
1
Before Using the Products
2
Preparation
3
Setup
4
Trial Run
5
Adjustment
6
When In T
roubie
7
Supplement
Pr7.37
RTEX command setting 3
Range
Unit
Attribute
Default
Related
control code
0 to 2
—
C
0
P S T
Specifies Sub_Command_Data3 of sub command.
setup value
Content
【
0
】
Invalid
1
Velocity feedforward [Command unit/s] or [r/min]
2
Torque feedforward [0.1 %]
Pr7.38
RTEX_Update_Counter error
protection setup
Range
Unit
Attribute
Default
Related
control code
0 to 32767
times
A
0
P S T
If the Update_Counter exceeds the setup value for this parameter and is not updated
correctly, Err 86.2 “RTEX_Update_Counter error protection” will be activated.
If the setup value is 0 or 1, this function will be disabled and an alarm will not be activated..
Pr7.39
For manufacturer’s use
Range
Unit
Attribute
Default
Related
control code
—
—
—
0
Pleses fixed to 0.
Pr7.40
For manufacturer’s use
Range
Unit
Attribute
Default
Related
control code
—
—
—
0
Pleses fixed to 0.
Pr7.41
RTEX function extended setup 5
Range
Unit
Attribute
Default
Related
control code
−32768 to 32767
—
R
0
P S T
bit0
to
6: Not used Pleses fixed to 0.
bit7
:
Run inhibit input detection setting when returning to origin of Z phase
0
:
Invalid
、
1
:
Valid
Pr7.43
For manufacturer’s use
Range
Unit
Attribute
Default
Related
control code
—
—
—
0
Pleses fixed to 0.
Pr7.52
For manufacturer’s use
Range
Unit
Attribute
Default
Related
control code
—
—
—
0
Pleses fixed to 0.
4. Details of Parameter