2-12
Rev.2.00
Sensor etg.
①
②
⑤
⑧
③
④
⑥
⑦
L1
U
X6
V
W
L2
L3
L1C
L2C
RTEX Communication
⑨
X4
X2B
X2A
NF2
NF1
Metaric control box
100 V/200 V
Insulated power supply
for interface
Power
supply
Surge
absorber
Noise filter
Protective earth (PE)
M
RE
Ferrite coil
Ferrite coil
Driver
Motor
Circuit
breaker
(MCCB)
Residual
current device
(RCD)
2. Conformance to International Standards
About Conformance to International Standards
Installation Environment
Use the servo driver in the environment of Pollution Degree 1 or 2 prescribed in IEC-
60664-1 (e.g. Install the driver in control panel with IP54 protection structure.)
• Mandatory requirements to conform to EMC directive
・
Install the servo driver on the metallic casing (control board).
・
Install noise filter and lightning surge absorber in the power supply line.
・
Use braided shield cable (tin plated annealed copper wire) for I/O signal cable and
encoder cable.
・
Provide the ferrite coil, as shown in the figure, for each cable, power source line and
motor line to be connected to the servo driver.
・
Shield of cables not shown on the figure should be directly grounded through PE.
Because these conditions for EMC directive are affected by status of connected de
vices, wiring, connection and location, compliance should be checked after complet
-
ing installation.