Rev.2.00
The connector X7 of the front panel is for monitor output.
Analogue output: 2 systems
It is possible to switch the output signal by setting parameters.
Connector X7
Measuring
instrument
Output circuit
1
1kΩ
AM1
GND 3
1kΩ
AM2 2
1
5
Title
Symbol
Connector
Pin No.
Description
Analog monitor output 1
AM1
1
Analog signal output for monitoring
Analog monitor output 2
AM2
2
Signal ground
GND
3
Connect to signal ground.
NC
—
4
Do not connect.
NC
—
5
Do not connect.
•
Relevant parameters of Monitor output
Parameter No.
Title of Parameter
Function
Class
No.
4
16
Type of analog
monitor 1
Select the type of monitor for analog monitor 1.
4
17
Analog monitor 1
output gain
Set up the output gain of analog monitor 1.
4
18
Type of analog
monitor 2
Select the type of monitor for analog monitor 2.
4
19
Analog monitor 2
output gain
Set up the output gain of analog monitor 2.
4
21
Analog monitor
output setup
Select output format of the analog monitor.
• Specifications of the Connector, X6
Cable Connector
Manufacturer
Part name
Part No.
Connector
51021-0500
Molex Inc.
Connector Pin
50058-8500
2
Preparation
10.
Wiring to the Connector, X7
Monitor Output
• X1 to X7 are used for the secondary circuit. To connect these terminals to the primary power
supply (particularly, the 24 VDC power supply for brake), insulation is required.
Do not connect these terminals to the same power supply.
•P.3-67
〜
“Details of Parameter”
Remarks
Related page