• Function allocatable to control input
Title of signal
Forced alarm input
Related control mode
P S
T
Symbol
E-STOP
RTEX communications
monitor
○
• Generates Err 87.0 ''Forced alarm input error''.
Title of signal
Positive direction over-travel inhibition input
Related control mode
P S
T
Symbol
POT
RTEX communications
monitor
○
• Positive direction over-travel inhibit input.
• The operation with this input turned ON is set up in Pr5.04 “Setup of over-travel inhibit
input”.
• When using setup of over-travel inhibit input by the host controller, set Pr5.04 to 1. and
comferm sepesfication of the host controller.
• When using this input, set Pr5.04 “Setup of over-travel inhibit input” to a value other
than 1 so that the input is ON when the moving portion of the machine exceeds this
signal range toward positive direction.
• If used as a home position reference trigger in a home position return, the input can
only be assigned to SI6 with Pr 5.04 set to 1 to disable the drive inhibit input. The
signal width should be 1 ms or longer then at the time of closing, and should be 2 ms
or longer then at the time of opening. Please keep in mind that it cannot guarantee this
value.
Title of signal
Negative direction over-travel inhibition input
Related control mode
P S
T
Symbol
NOT
RTEX communications
monitor
○
• Positive direction over-travel inhibit input.
• The operation with this input turned ON is set up in Pr5.04 “Setup of over-travel inhibit
input”.
• When using setup of over-travel inhibit input by the host controller, set Pr5.04 to 1. and
comferm sepesfication of the host controller.
• When using this input, set Pr5.04 “Setup of over-travel inhibit input” to a value other
than 1 so that the input is ON when the moving portion of the machine exceeds this
signal range toward positive direction.
• If used as a home position reference trigger in a home position return, the input can
only be assigned to SI7 with Pr 5.04 set to 1 to disable the drive inhibit input. The
signal width should be 1 ms or longer then at the time of closing, and should be 2 ms
or longer then at the time of opening. Please keep in mind that it cannot guarantee this
value.
Title of signal
Near home input
Related control mode
P S
T
Symbol
HOME
RTEX communications
monitor
○
• When using the near home sensor during the return to home position operation,
input the sensor signal, and External signal input in a home position return.
• If used as a home position reference trigger in a home position return, the input can
only be assigned to SI5, respectively.
8.
Wiring to the Connector, X4
Input Signal and Pin No.
•P.3-64 “Details of Parameter”
•P.6-3 “Protection Function”
Related page