2-56
Rev.2.00
Title of signal
Positioning complete 2
Related control mode
*
1
P
S
T
Symbol
INP2
RTEX communications
monitor
*
2
—
• Outputs the positioning complete signal 2. Turns ON the output transistor upon
completion of positioning.
• For details, refer to P.3-74.
Title of signal
Alarm output 1
Related control mode
*
1
P S
T
Symbol
WARN1
(Warning)
RTEX communications
monitor
*
2
△
• Outputs the warning output signal set to Pr4.40 “Warning output select 1”. Turns ON
the output transistor upon occurrence of warning condition.
Title of signal
Alarm output 2
Related control mode
*
1
P S
T
Symbol
WARN2
(Warning)
RTEX communications
monitor
*
2
△
• Outputs the warning output signal set to Pr4.41 “Warning output select 2”. Turns ON
the output transistor upon occurrence of warning condition.
Title of signal
Positional command ON/OFF output
Related control mode
*
1
P
S
T
Symbol
P-CMD
(In_Progress)
RTEX communications
monitor
*
2
○
• Outputs the Positional command ON/OFF signal 2. Turns on the output transistor
when the positioning command (before filter) is other than 0 (with positioning
command).
Title of signal
Speed command ON/OFF
output
Related control mode
*
1
P S
T
Symbol
V-LIMIT
RTEX communications
monitor
*
2
—
•
Turns on output transistor when the speed command is applied while the speed is
controlled. Turns on the output transistor when velocity is limited.
Title of signal
Alarm clear attribute output
Related control mode
*
1
P S
T
Symbol
ALM-ATB
RTEX communications
monitor
*
2
—
• The signal is output if an alarm has occurred and if it can be cleared, turns on the
output transistor when an alarm occurs.
8. Wiring to the Connector
, X4
Output Signal and Pin No.
*1 With unrelated control mode, the output transistor is always turned off.
*2
“
RTEX communications monitor
”
in the table is the response of RTEX communication and
therefore monitor.
○
No allocation is made to the response (status flag) of RTEX communication and therefore
monitor is possible.
− No allocation is made to the response (status flag) of RTEX communication and therefore
monitor is impossible.
△
The status flag [Warning] of RTEX communication is turned ON whenever any warning is
generated, regardless of setting value of Pr 4.40 or Pr 4.41.
The designation in ( ) in [Sign] column in the table shows the symbol used in RTEX
communications.
(
Notice that detection conditions of external output signal and RTEX communication signal are not
the same.
)
For details, refer to Technical Reference of controller.