background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User Manual 

 
 
 
 
 

OSD2512 

MANAGED 12 x 10/100/1000BASE-T (RJ45) 

AND 2 x 1G (SFP) ETHERNET SWITCH 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for OSD2512

Page 1: ...User Manual OSD2512 MANAGED 12 x 10 100 1000BASE T RJ45 AND 2 x 1G SFP ETHERNET SWITCH...

Page 2: ......

Page 3: ...TION 20 USERS AUTHENTICATION 21 SAVE CONFIGURATION TO START UP 23 4 USER MANUAL 24 4 1 TECHNICAL SPECIFICATIONS 24 4 2 INSTALLATION 25 4 3 OSD2512 DIMENSIONS 26 5 OSD2512 FRONT AND REAR PANELS 27 5 1...

Page 4: ...ION 123 LINK OAM CONFIGURATION 126 LOOP PROTECTION 130 SPANNING TREE 132 IPMC PROFILE CONFIGURATIONS 141 MVR CONFIGURATIONS 145 IPMC 148 NAVIGATING THE IGMP SNOOPING VLAN TABLE 151 IGMP SNOOPING VLAN...

Page 5: ...PORT 243 SOURCE VLAN S CONFIGURATION 243 REMOTE MIRRORING PORT CONFIGURATION 243 CONFIGURATION GUIDELINE FOR ALL FEATURES 244 UPNP CONFIGURATION 246 PTP EXPERNAL CLOCK MODE 247 PTP EXTERNAL CLOCK CON...

Page 6: ...LE COLUMNS 313 RADIUS SERVERS 315 RADIUS AUTHENTICATION STATISTICS 317 RADIUS ACCOUNTING STATISTICS 320 AGGREGATION 332 AGGREGATION GROUP STATUS 332 LOOP PROTECTION STATUS 337 SPANNING TREE 338 MVR 34...

Page 7: ...ICS 387 9 5 MAINTENANCE 389 RESTART DEVICE 389 FACTORY DEFAULTS 390 SOFTWARE 391 IMAGE INFORMATION 392 CONFIGURATION 393 10 WARRANTY 398 10 1 WARRANTY PERIOD 398 10 2 REPAIRS 398 WARRANTY REPAIRS 398...

Page 8: ...major benefit of the OSD2512 is its reliable and consistent performance over the 25 C to 70 C temperature range 2 FUNCTIONAL DESCRIPTION Managed L2 switch for small to medium sized enterprise network...

Page 9: ...Link down power savings Scales power based on cable length Thermal protection Management HTTP server Web management CLI console port Management access filtering System log Software download through we...

Page 10: ...FRONT PANEL 1 Board Status LED 2 USB Console Port 3 View LED Mode Button 4 View Mode LEDs Indicators 5 Copper Port Status LEDs 6 RJ45 Copper Ports 7 SFP Fiber LED 8 SFP Fiber Ports 9 SFP Fiber LED 10...

Page 11: ...Connect the dual redundant power to the 4 way terminal block located on the rear of the unit The OSD2512 requires external 10 to 36VDC 40VA Max power FIGURE 3 POWER CONNECTION TABLE 1 DC POWER CONNECT...

Page 12: ...de button cycles the Copper Port Status LED indication Speed Mode Duplex Mode Status Mode Reserved Copper Port Status LED The Copper Port Status LED will indicate different information Speed Mode Gree...

Page 13: ...stalling Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until...

Page 14: ...L SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 14 3 5 CLI OVERVIEW CONNECT TO CLI The Silicon Laboratories CP210x VCP Drivers is needed to be installed on the PC before connecting the s...

Page 15: ...ntrol None 3 Check the link by pressing ENTER The line should jump to the next line 4 Using the Username and password to login the switch 5 If there is no user input for a period of time the user will...

Page 16: ...of CLI commands available with a brief description will be displayed Some terminal emulators like SecureCRT support the Tab key At the prompt pressing the Tab key will also produce a list of availabl...

Page 17: ...ady to enter a command argument eg show and describes each possible argument 2 Partial help is provided when an abbreviated argument is entered and user wants to know what arguments match the input eg...

Page 18: ...t is in configuration mode the user can change detailed configurations To set the OSD2512 host name the unit needs to be first set to configuration mode then enter the hostname command then a chosen h...

Page 19: ...ure terminal config interface vlan 1 config if vlan ip address dhcp fallback 192 168 0 99 255 255 0 0 config if vlan exit Note IP addresses can only be assigned to VLAN interfaces After configuration...

Page 20: ...r enter the URL 192 168 0 99 Enter the username and password IP CONFIGURATION In the treemap on the left expand the Configuration System IP Enter the IPv4 address and Mask Length in the table Choose t...

Page 21: ...01 OSD2512 OPERATOR MANUAL PAGE 21 USERS AUTHENTICATION In the tree map on the left expand the Configuration Security Switch Users Click admin to change the current admin account setting If multiple u...

Page 22: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 22 PS All configuration changes must be saved otherwise all the changes will be lost after rebooting...

Page 23: ...18101 OSD2512 OPERATOR MANUAL PAGE 23 SAVE CONFIGURATION TO START UP In the treemap below expand the Maintenance and expand Configuration then select Save startup config Click Save Configuration to sa...

Page 24: ...0 100 Full duplex for 1G Store and Forward Half duplex back pressure and IEEE802 3x full duplex flow control Optical Optical Port Connectors SFP SFP Options Short haul long haul single fiber operation...

Page 25: ...service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures during servicing of equipment Areas where laser products are ins...

Page 26: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 26 4 3 OSD2512 DIMENSIONS 442mm 200mm 44mm...

Page 27: ...Board Status LED 16 USB Console Port 17 View LED Mode Button 18 View Mode LEDs Indicators 19 Copper Port Status LEDs 20 RJ45 Copper Ports 21 SFP Fiber LED 22 SFP Fiber Ports 23 SFP Fiber LED 24 Reset...

Page 28: ...onnect the dual redundant power to the 4 way terminal block located on the rear of the unit The OSD2512 requires external 10 to 36VDC 40VA Max power FIGURE 7 POWER CONNECTION TABLE 3 DC POWER CONNECTI...

Page 29: ...e button cycles the Copper Port Status LED indication Speed Mode Duplex Mode Status Mode Reserved Copper Port Status LED The Copper Port Status LED will indicate different information Speed Mode Green...

Page 30: ...talling Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until...

Page 31: ...tch port and power the unit Open a web browser window Firefox IEx etc Enter the IP address of the switch on the web browser The default IP address assigned to the OSD2512 is 192 168 0 99 A login windo...

Page 32: ...ollows Menu can be expanded to show sub menus by clicking the heading Menu is expanded and sub menus are displayed Clicking the heading will close the submenu Menu title Clicking will open the GUI win...

Page 33: ...tratively assigned name for this managed node By convention this is the node s fully qualified domain name A domain name is a text string drawn from the alphabet A Za z digits 0 9 minus sign No space...

Page 34: ...In Router mode traffic is routed between all interfaces DNS Server This setting controls the DNS name resolution done by the switch There are four servers available for configuration and the index of...

Page 35: ...should be preferred From any DHCPv6 interfaces The first DNS server offered from a DHCPv6 lease to a DHCPv6 enabled interface will be used DNS Proxy When DNS proxy is enabled system will relay DNS req...

Page 36: ...nable the DHCPv6 client by checking this box If this option is enabled the system will configure the IPv6 address of the interface using the DHCPv6 protocol DHCPv6 Rapid Commit Enable the DHCPv6 Rapid...

Page 37: ...route can use the value 0 0 0 0or IPv6 notation Mask Length The destination IP network or host mask in number of bits prefix length It defines how much of a network address that must match in order to...

Page 38: ...ress is in 128 bit records represented as eight fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can b...

Page 39: ...ne This page allows you to configure the Time Zone Time Zone Configuration Time Zone Lists various Time Zones world wide Select appropriate Time Zone from the drop down and click Save to set Acronym U...

Page 40: ...me configuration Default Disabled Recurring Configurations Start time settings Week Select the starting week number Day Select the starting day Month Select the starting month Hours Select the startin...

Page 41: ...e ending year Hours Select the ending hour Minutes Select the ending minute Offset settings Offset Enter the number of minutes to add during Daylight Saving Time Range 1 to 1440 Buttons Click to save...

Page 42: ...ot exist Possible modes are Enabled Enable server mode operation Disabled Disable server mode operation Server Address Indicates the IPv4 host address of syslog server If the switch provide DNS featur...

Page 43: ...mperature sensor the highest temperature is used for controlling the fan Max Temperature The temperature at which the fan will be to set to run at full speed The value accepted is within the range of...

Page 44: ...in a block 1 high for SFPs 2 high for RJ45s to the left of the ports A pushbutton and a 4 high tower of LEDs is placed next to the front ethernet port LEDs The pushbutton selects between four differen...

Page 45: ...sity 100 Full power 0 LED off MAINTENANCE On time at link change When a network administrator does maintenance of the switch e g adding or moving users he might want to have full LED intensity during...

Page 46: ...ion EEE works by powering down circuits when there is no traffic When a port gets data to be transmitted all circuits are powered up The time it takes to power up the circuits is named wakeup time The...

Page 47: ...ActiPHY works by lowering the power for a port when there is no link The port is power up for short moment in order to determine if cable is inserted PerfectReach Cable length power savings enabled Pe...

Page 48: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 48 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 49: ...ANUAL PAGE 49 THERMAL PROTECTION CONFIGURATION Configuration Thermal Protection This page allows the user to inspect and configure the current setting for controlling thermal protection Thermal protec...

Page 50: ...s with different groups Each group can be given a temperature at which the corresponding ports shall be turned off Temperature settings for groups The temperature at which the ports with the correspon...

Page 51: ...eed Selects any available link speed for the given switch port Only speeds supported by the specific port is shown Possible speeds are Disabled Disables the switch port operation Auto Port auto negoti...

Page 52: ...The Rx and Tx settings are determined by the result of the last Auto Negotiation Check the configured column to use flow control This setting is related to the setting for Configured Link Speed NOTIC...

Page 53: ...3 frame length mismatch Note No drop counters count frames dropped due to frame length mismatch Buttons Click to save changes Click to undo any changes made locally and revert to previously saved valu...

Page 54: ...AGE 54 DHCP SERVER DHCP Server Mode Configuration Configuration DHCP Server Mode This page configures global mode and VLAN mode to enable disable DHCP server per system and per VLAN GLOBAL MODE Config...

Page 55: ...ther one of the first and second VLAN ID or both On the other hand if you want to disable existed VLAN range then you can follow the steps 1 Press to add a new VLAN range 2 Input the VLAN range that y...

Page 56: ...EXCLUDED IP ADDRESS Configure excluded IP addresses IP Range Define the IP range to be excluded IP addresses The first excluded IP must be smaller than or equal to the second excluded IP BUT if the IP...

Page 57: ...pts all printable characters except white space If you want to configure the detail settings you can click the pool name to go into the configuration page Type Display which type of the pool is Networ...

Page 58: ...Snooping on this page Snooping Mode Indicates the DHCP snooping mode operation Possible modes are Enabled Enable DHCP snooping mode operation When DHCP snooping mode operation is enabled the DHCP requ...

Page 59: ...tes the DHCP snooping port mode Possible port modes are Trusted Configures the port as trusted source of the DHCP messages Untrusted Configures the port as untrusted source of the DHCP messages Button...

Page 60: ...ed for security considerations Disabled Disable DHCP relay mode operation Relay Server Indicates the DHCP relay server IP address Relay Information Mode Indicates the DHCP relay information mode optio...

Page 61: ...Replace policy is invalid when relay information mode is disabled Possible policies are Replace Replace the original relay information when a DHCP message that already contains it is received Keep Kee...

Page 62: ...k to Add Edit User Privilege Level The privilege level of the user The allowed range is 0 to 15 If the privilege level value is 15 it can access all groups i e that is granted the fully control of the...

Page 63: ...8101 OSD2512 OPERATOR MANUAL PAGE 63 15 Generally the privilege level 15 can be used for an administrator account privilege level 10 for a standard user account and privilege level 5 for a guest accou...

Page 64: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 64 Privilege Level Configuration Configuration Security Switch Privilege Levels...

Page 65: ...tenance Debug Only present in CLI Privilege Levels Every group has an authorization Privilege level for the following sub groups configuration read only configuration execute read write status statist...

Page 66: ...the management client interfaces The table has one row for each client type and a number of columns which are Client The management client for which the configuration below applies Methods Method can...

Page 67: ...one of the following values No Command authorization is disabled User is granted access to CLI commands according to his privilege level Tacacs Use remote TACACS server s for command authorization If...

Page 68: ...L SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 68 Exec Enable exec login accounting Buttons Click to save changes Click to undo any changes made locally and revert to previously saved v...

Page 69: ...figuration Security Switch SSH Configure SSH on this page Mode Indicates the SSH mode operation Possible modes are Enabled Enable SSH mode operation Disabled Disable SSH mode operation Buttons Click t...

Page 70: ...certificate is trusted to the browser You need to initialize the HTTPS connection manually for this case Possible modes are Enabled Enable HTTPS redirect mode operation Disabled Disable HTTPS redirect...

Page 71: ..._path new_image dat http username password 10 10 10 10 80 new_image_path new_image dat A valid file name is a text string drawn from alphabet A Za z digits 0 9 dot hyphen under score _ The maximum len...

Page 72: ...ete the entry It will be deleted during the next save VLAN ID Indicates the VLAN ID for the access management entry Start IP address Indicates the start IP address for the access management entry End...

Page 73: ...STEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 73 Buttons Click to add a new access management entry Click to save changes Click to undo any changes made locally and revert to previously sa...

Page 74: ...MP System Configure SNMP on this page Mode Indicates the SNMP mode operation Possible modes are Enabled Enable SNMP mode operation Disabled Disable SNMP mode operation Version Indicates the SNMP suppo...

Page 75: ...rite access string to permit access to SNMP agent The allowed string length is 0 to 255 and the allowed content is the ASCII characters from 33 to 126 The field is applicable only when SNMP version is...

Page 76: ...SNMP trap mode operation TRAP DESTINATION CONFIGURATIONS Configure trap destinations on this page Name Indicates the trap Configuration s name Indicates the trap destination s name Enable Indicates t...

Page 77: ...address IPv6 address is in 128 bit records represented as eight fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special...

Page 78: ...agent The allowed string length is 1 to 32 and the allowed content is ASCII characters from 33 to 126 The community string will be treated as security name and map a SNMPv1 or SNMPv2c community strin...

Page 79: ...er can communicate In other words if user engine ID equal system engine ID then it is local user otherwise it s remote user User Name A string identifying the user name that this entry should belong t...

Page 80: ...ivacy protocol that this entry should belong to Possible privacy protocols are None No privacy protocol DES An optional flag to indicate that this user uses DES authentication protocol AES An optional...

Page 81: ...ity models are v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Name A string identifying the security name that this entry should belong to The allowed strin...

Page 82: ...this entry should belong to Possible view types are included An optional flag to indicate that this view subtree should be included excluded An optional flag to indicate that this view subtree should...

Page 83: ...t this entry should belong to Possible view types are included An optional flag to indicate that this view subtree should be included excluded An optional flag to indicate that this view subtree shoul...

Page 84: ...ete the entry It will be deleted during the next save ID Indicates the index of the entry The range is from 1 to 65535 Data Source Indicates the port ID which wants to be monitored If in stacking swit...

Page 85: ...tacking switch the value must add 1000000 switch ID 1 for example if the port is switch 3 port 5 the value is 2000005 Interval Indicates the interval in seconds for sampling the history statistics dat...

Page 86: ...number of inbound packets that are discarded even the packets are normal InErrors The number of inbound packets that contained errors preventing them from being deliverable to a higher layer protocol...

Page 87: ...allingTrigger alarm when the first value is less than the falling threshold RisingOrFallingTrigger alarm when the first value is larger than the rising threshold or less than the falling threshold def...

Page 88: ...the notification of the event the possible types are none No SNMP log is created no SNMP trap is sent log Create SNMP log entry when the event is triggered snmptrap Send SNMP trap when the event is tr...

Page 89: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 89 NETWORK CONFIGURATION Port Security Limit Control Configuration Configuration Security Network Limit Control...

Page 90: ...o the aging period The underlying port security will use the shorter requested aging period of all modules that use the functionality The Aging Period can be set to a number between 10 and 10 000 000...

Page 91: ...ort by disconnecting the cable the port will remain shut down There are three ways to re open the port 1 Boot the switch 2 Disable and re enable Limit Control on the port or the switch 3 Click the Reo...

Page 92: ...a port based access control procedure that prevents unauthorized access to a network by requiring users to first submit credentials for authentication One or more central servers the backend servers...

Page 93: ...ion Period Determines the period in seconds after which a connected client must be reauthenticated This is only active if the Reauthentication Enabled checkbox is checked Valid values are in the range...

Page 94: ...ecked RADIUS server assigned QoS Class is disabled on all ports RADIUS Assigned VLAN Enabled RADIUS assigned VLAN provides a means to centrally control the VLAN on which a successfully authenticated s...

Page 95: ...rt will be allowed network access without authentication FORCE UNAUTHORIZED In this mode the switch will send one EAPOL Failure frame when the port link comes up and any client on the port will be dis...

Page 96: ...y authenticated only that supplicant will be allowed access This is the most secure of all the supported modes In this mode the Port Security module is used to secure a supplicant s MAC address once s...

Page 97: ...ilable for single client modes i e Port based 802 1X Single 802 1X RADIUS attributes used in identifying a QoS Class The User Priority Table attribute defined in RFC4675 forms the basis for identifyin...

Page 98: ...e interval between transmission of EAPOL Request Identity frames is configured with EAPOL Timeout If Allow Guest VLAN if EAPOL Seen is enabled the port will now be placed in the Guest VLAN If disabled...

Page 99: ...ut EAPOL based authentication For MAC based authentication reauthentication will be attempted immediately The button only has effect for successfully authenticated clients on the port and will not cau...

Page 100: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 100 ACL Configuration Configuration Security Network ACL ACL Port Configuration Configuration Security Network ACL Ports...

Page 101: ...rect Select which port frames are redirected on The allowed values are Disabled or a specific port number and it can t be set when action is permitted The default value is Disabled Mirror Specify the...

Page 102: ...on of the ACL user module Disabled To close ports by changing the volatile port configuration of the ACL user module The default value is Enabled Counter Counts the number of frames that match this AC...

Page 103: ...f the switch Rate Limiter ID The rate limiter ID for the settings contained in the same row and its range is 1 to 16 Rate The valid rate is 0 3276700 in pps or 0 100 200 300 1000000 in kbps Unit Speci...

Page 104: ...ll match a specific ingress port Policy Bitmask Indicates the policy number and bitmask of the ACE Frame Type Indicates the frame type of the ACE Possible values are Any The ACE will match any frame t...

Page 105: ...ror port The allowed values are Enabled Frames received on the port are mirrored Disabled Frames received on the port are not mirrored The default value is Disabled Counter The counter indicates the n...

Page 106: ...GN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 106 IP Source Guard Configuration Configuration Security Network IP Source Guard IP Source Guard Configuration Configuration Security Network IP Source...

Page 107: ...on which ports Only when both Global Mode and Port Mode on a given port are enabled IP Source Guard is enabled on this given port Max Dynamic Clients Specify the maximum number of dynamic clients tha...

Page 108: ...er of rules is 112 on the switch Delete Check to delete the entry It will be deleted during the next save Port The logical port for the settings VLAN ID The vlan id for the settings IP Address Allowed...

Page 109: ...GN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 109 ARP Inspection Configuration Configuration Security Network ARP Inspection ARP Inspection Configuration Configuration Security Network ARP Inspectio...

Page 110: ...ion is enabled on this given port Possible modes are Enabled Enable ARP Inspection operation Disabled Disable ARP Inspection operation If you want to inspect the VLAN configuration you have to enable...

Page 111: ...sabled the log type of ARP Inspection will refer to the port setting There are four log types and possible types are None Log nothing Deny Log denied entries Permit Log permitted entries ALL Log all e...

Page 112: ...Table Clicking the button will update the displayed table starting from that or the closest next VLAN Table match The will use the next entry of the currently displayed VLAN entry as a basis for the...

Page 113: ...GN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 113 Buttons Click to add a new entry to the Static IP Source Guard table Click to save changes Click to undo any changes made locally and revert to prev...

Page 114: ...e switch Delete Check to delete the entry It will be deleted during the next save Port The logical port for the settings VLAN ID The vlan id for the settings MAC Address Allowed Source MAC address in...

Page 115: ...ries from the beginning of the Dynamic ARP Inspection Table The Start from port address VLAN MAC address and IP address input fields allow the user to select the starting point in the Dynamic ARP Insp...

Page 116: ...Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Click to save changes Click to undo...

Page 117: ...R MANUAL PAGE 117 AAA CONFIGURATION Configuration Security AAA RADIUS Server Configuration Configuration Security AAA RADIUS This page allows you to configure the RADIUS servers GLOBAL CONFIGURATION T...

Page 118: ...e switch NAS IP Address Attribute 4 The IPv4 address to be used as attribute 4 in RADIUS Access Request packets If this field is left blank the IP address of the outgoing interface is used NAS IPv6 Ad...

Page 119: ...the global key Leaving it blank will use the global key ADDING A NEW SERVER Click to add a new RADIUS server An empty row is added to the table and the RADIUS server can be configured as needed Up to...

Page 120: ...time which can be set to a number between 0 to 1440 minutes is the period during which the switch will not send new requests to a server that has failed to respond to a previous request This will stop...

Page 121: ...lobal timeout value Leaving it blank will use the global timeout value Key This optional setting overrides the global key Leaving it blank will use the global key ADDING A NEW SERVER Click to add a ne...

Page 122: ...Aggregation Static This page is used to configure the Aggregation hash mode and the aggregation group HASH CODE CONTRIBUTORS Source MAC Address The Source MAC address can be used to calculate the dest...

Page 123: ...ation port for the frame Check to enable the use of the TCP UDP Port Number or uncheck to disable By default TCP UDP Port Number is enabled AGGREGATION GROUP CONFIGURATION Group ID Indicates the group...

Page 124: ...bled Controls whether LACP is enabled on this switch port LACP will form an aggregation when 2 or more ports are connected to the same partner Key The Key value incurred by the port range 1 65535 The...

Page 125: ...ssions Fast will transmit LACP packets each second while Slow will wait for 30 seconds before sending a LACP packet Prio The Prio controls the priority of the port range 1 65535 If the LACP partner wa...

Page 126: ...network and quickly determine the location of failing links or fault conditions OAM Mode Configures the OAM Mode as Active or Passive The default mode is Passive ACTIVE MODE DTE s configured in Activ...

Page 127: ...opback support will allow the DTE to execute the remote loopback command that helps in the fault detection Link Monitor Support Controls whether the Link Monitor support is enabled for the switch port...

Page 128: ...is generated if the errored frame count is equal to or greater than the specified threshold for that period Period Threshold Errored frames are frames that had transmission errors as detected at the M...

Page 129: ...r greater than the specified threshold for that period An errored frame second is a one second interval wherein at least one frame error was detected Errored frames are frames that had transmission er...

Page 130: ...DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 130 LOOP PROTECTION Configuration Loop Protection This page allows the user to inspect the current Loop Protection configurations and possibly chan...

Page 131: ...ort Valid values are 0 to 604800 seconds 7 days A value of zero will keep a port disabled until next device restart Default value is 180 seconds Port Configuration Port The switch port number of the p...

Page 132: ...RIDGE CONFIGURATION Configuration Spanning Tree Bridge Settings This page allows you to configure STP system settings The settings are used by all STP Bridge instances in the Switch Basic Settings Pro...

Page 133: ...t This defines the initial value of remaining Hops for MSTI information generated at the boundary of an MSTI region It defines how many bridges a root bridge can distribute its BPDU information to Val...

Page 134: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 134 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 135: ...urrent STP MSTI bridge instance priority configurations and possibly change them as well Configuration Identification Configuration Name The name identifying the VLAN to MSTI mapping Bridges must shar...

Page 136: ...will receive the VLANs not explicitly mapped VLANs Mapped The list of VLANs mapped to the MSTI The VLANs can be given as a single xx xx being between 1 and 4094 VLAN or a range xx yy each of which mus...

Page 137: ...ions and possibly change them as well MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower numeric values have better priority T...

Page 138: ...ber of the logical STP port STP Enabled Controls whether STP is enabled on this switch port Path Cost Controls the path cost incurred by the port The Auto setting will set the path cost as appropriate...

Page 139: ...region of the network influence the spanning tree active topology possibly because those bridges are not under the full control of the administrator This feature is also known as Root Guard Restricte...

Page 140: ...physical and aggregated ports Port The switch port number of the corresponding STP CIST and MSTI port Path Cost Controls the path cost incurred by the port The Auto setting will set the path cost as...

Page 141: ...ate at maximum 64 Profiles with at maximum 128 corresponding rules for each Global Profile Mode Enable Disable the Global IPMC Profile System starts to do filtering based on profile settings only when...

Page 142: ...ck the edit button to enter the rule setting page of the designated profile Summary about the designated profile will be shown by clicking the view button You can manage or inspect the rules of the de...

Page 143: ...e at maximum 128 address entries in the system Delete Check to delete the entry The designated entry will be deleted during the next save Entry Name The name used for indexing the address entry table...

Page 144: ...esses Click Save Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the displayed table starting from the input fields Updates the table start...

Page 145: ...ision application a PC or a network television or a set top box can receive the multicast stream Multiple set top boxes or PCs can be connected to one subscriber port which is a switch port configured...

Page 146: ...ets or numbers When the optional MVR VLAN name is given it should contain at least one alphabet MVR VLAN name can be edited for the existing MVR VLAN entries or it can be added to the new entries IGMP...

Page 147: ...ofile Port The logical port for the settings Port Role Configure an MVR port of the designated MVR VLAN as one of the following roles Inactive The designated port does not participate MVR operations S...

Page 148: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 148 IPMC IGMP SNOOPING Basic Configuration Configuration IPMC IGMP Snooping Basic Configuration...

Page 149: ...guration Snooping Enabled Enable the Global IGMP Snooping Unregistered IPMCv4 Flooding Enabled Enable unregistered IPMCv4 traffic flooding The flooding control takes effect only when IGMP Snooping is...

Page 150: ...ide Proxy Enabled Enable IGMP Proxy This feature can be used to avoid forwarding unnecessary join and leave messages to the router side Router Port Specify which ports act as router ports A router por...

Page 151: ...displayed entry as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over IGMP SNOOPING VLAN TABLE COLUMNS Delete Che...

Page 152: ...The allowed range is 1 to 31744 seconds default query interval is 125 seconds QRI Query Response Interval The Maximum Response Delay used to calculate the Maximum Response Code inserted into the peri...

Page 153: ...hanges made locally and revert to previously saved values Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the IPMC Profile Address Confi...

Page 154: ...Profile Select the IPMC Profile as the filtering condition for the specific port Summary about the designated profile will be shown by clicking the view button Profile Management Button You can inspec...

Page 155: ...18101 OSD2512 OPERATOR MANUAL PAGE 155 MLD SNOOPING MLD Snooping Configuration Configuration IPMC MLD Snooping Basic Configuration This page provides MLD Snooping related configuration Snooping Enable...

Page 156: ...eave Proxy Enabled Enable MLD Leave Proxy This feature can be used to avoid forwarding unnecessary leave messages to the router side Proxy Enabled Enable MLD Proxy This feature can be used to avoid fo...

Page 157: ...ext closest VLAN Table match The will use the last entry of the currently displayed entry as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed tabl...

Page 158: ...val is 100 in tenths of seconds 10 seconds LLQI Last Listener Query Interval The Last Listener Query Interval is the Maximum Response Delay used to calculate the Maximum Response Code inserted into Mu...

Page 159: ...OR MANUAL PAGE 159 Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the IPMC Profile Address Configuration Updates the table starting wit...

Page 160: ...rofile Select the IPMC Profile as the filtering condition for the specific port Summary about the designated profile will be shown by clicking the view button Profile Management Button You can inspect...

Page 161: ...PTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 161 LLDP LLDP CONFIGURATION Configuration LLDP This page allows the user to inspect and configure the current LLDP interface settings...

Page 162: ...tricted to 1 10 seconds LLDP INTERFACE CONFIGURATION Interface The switch interface name of the logical LLDP interface Mode Select LLDP mode Rx only The switch will not send out LLDP information but L...

Page 163: ...sabled the CDP information isn t removed immediately but gets removed when the hold time is exceeded Port Descr Optional TLV When checked the port description is included in LLDP information transmitt...

Page 164: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 164 LLDP MED CONFIGURATION Configuration LLDP MED...

Page 165: ...transmission of the LLDPDU to start within a second when a new LLDP MED neighbor has been detected in order share LLDP MED information as fast as possible to new neighbors Because there is a risk of a...

Page 166: ...2097151 9 to 2097151 9 with a maximum of 1 digits It is possible to select between two altitude types floors or meters Meters Representing meters of Altitude defined by the vertical datum specified Fl...

Page 167: ...ddress location will use 2 extra characters in addtion to the civic address location text 2 The 2 letter country code is not part of the 250 characters limitation Country code The two letter ISO 3166...

Page 168: ...o Room number Example 450F Place type Place type Example Office Postal community name Postal community name Example Leonia P O Box Post office box P O BOX Example 12345 Additional code Additional code...

Page 169: ...2474 This network policy is potentially advertised and associated with multiple sets of application types supported on a given port The application types specifically addressed are 1 Voice 2 Guest Voi...

Page 170: ...he guest voice signalling than for the guest voice media This application type should not be advertised if all the same network policies apply as those advertised in the Guest Voice application policy...

Page 171: ...for the specified application type L2 Priority may specify one of eight priority levels 0 through 7 as defined by IEEE 802 1D 2004 A value of 0 represents use of the default priority as defined in IEE...

Page 172: ...PTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 172 Buttons Click to add new Policy Click to save changes Click to undo any changes made locally and revert to previously saved value...

Page 173: ...on SyncE This page allows the user to inspect and configure the current SyncE port settings CLOCK SOURCE NOMINATION AND STATE For each possible clock source the following can be configured Clock Sourc...

Page 174: ...ocess SSM Overwrite A selectable clock source Quality Level QL to overwrite any QL received in a SSM If QL is not Received in a SSM SSM is not enabled on this port the SSM Overwrite QL is used as if r...

Page 175: ...it To Restore timer value in minutes The WTR time is activated on the falling edge of a clock source failure in Revertive mode This means that the clock source is first available for clock selection a...

Page 176: ...2 048 MHz or 10 MHz Clock Output frequency If supported by the Synce HW the station clock output frequency can be configured the possible frequencies are 1 544 MHz 2 048 MHz or 10 MHz SYNCE PORTS For...

Page 177: ...GN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 177 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the displayed table starting fr...

Page 178: ...k on the ID of an EPS to enter the configuration page The range is 1 100 Domain Port This will create a EPS in the Port Domain W P Flow is a Port Architecture Port This will create a 1 1 EPS Port This...

Page 179: ...8101 OSD2512 OPERATOR MANUAL PAGE 179 Buttons Click to add a new EPS entry Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the displayed ta...

Page 180: ...MEP in the EVC Domain Flow Instance is an EVC The EVC must be created VLAN This is a MEP in the VLAN Domain Flow Instance is a VLAN In case of Up MEP the VLAN must be created Mode MEP This is a Mainte...

Page 181: ...ded EVC MEP This is not used VLAN MEP This is not used EVC MIP On Serval this is the Subscriber VID that identify the subscriber flow in this EVC where the MIP is active This MAC The MAC of this MEP c...

Page 182: ...s instance Port 0 SF MEP The Port 0 Signal Fail reporting MEP Port 1 SF MEP The Port 1 Signal Fail reporting MEP As only one SF MEP is associated with interconnected sub ring without virtual channel i...

Page 183: ...ing doesn t have virtual channel Major Ring ID Major ring group ID for the interconnected sub ring It is used to send topology change updates on major ring If ring is major this value is same as the p...

Page 184: ...on this page Set timeouts for entries in the dynamic MAC Table and configure the static MAC table here AGING CONFIGURATION By default dynamic entries are removed from the MAC table after 300 seconds...

Page 185: ...managing the switch is added to the Static Mac Table before changing to secure learning mode otherwise the management link is lost and can only be restored by using another non secure port or by conn...

Page 186: ...12 OPERATOR MANUAL PAGE 186 Buttons Click to add a new entry to the static MAC table Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the di...

Page 187: ...s in other modes are members of the VLANs specified in the Allowed VLANs field By default only VLAN 1 is enabled More VLANs may be created by using a list syntax where the individual elements are sepa...

Page 188: ...s all frames are transmitted untagged Trunk Trunk ports can carry traffic on multiple VLANs simultaneously and are normally used to connect to other switches Trunk ports have the following characteris...

Page 189: ...ill be tagged with a C tag S Port On egress if frames must be tagged they will be tagged with an S tag On ingress frames with a VLAN tag with TPID 0x88A8 get classified to the VLAN ID embedded in the...

Page 190: ...ng Port Type tag are accepted on ingress Untagged Only Only untagged frames are accepted on ingress See Port Type for a description of when a frame is considered untagged Egress Tagging Ports in Trunk...

Page 191: ...D2512 OPERATOR MANUAL PAGE 191 By default the field is left blank which means that the port may become a member of all possible VLANs Buttons Click to save changes Click to undo any changes made local...

Page 192: ...n Port to Group Configuration This page allows you to configure switch Ports to use a given VLAN Translation Mapping Group This will enable all VLAN Translation mappings of that group if any on the se...

Page 193: ...possible groups in a switch is equal to the number of ports present in this switch A port can be configured to use any of the groups but only one at any given time Multiple ports can be configured to...

Page 194: ...to use the same group A valid Group ID is an integer value from 1 to 14 Note By default each port is set to use the group with Group ID equal to the port number For example port 1 is by default set to...

Page 195: ...port must be a member of both a VLAN and a Private VLAN to be able to forward packets By default all ports are VLAN unaware and members of VLAN 1 and Private VLAN 1 A VLAN unaware port can only be a...

Page 196: ...ning message appears Click OK to discard the incorrect entry or click Cancel to return to the editing and make a correction The Private VLAN is enabled when you click Save The button can be used to un...

Page 197: ...Private VLAN CONFIGURATION Port Members A check box is provided for each port of a private VLAN When checked port isolation is enabled on that port When unchecked port isolation is disabled on that po...

Page 198: ...lete a MAC to VLAN ID mapping entry check this box and press save The entry will be deleted in the stack MAC Address Indicates the MAC address of the mapping VLAN ID Indicates the VLAN ID the above MA...

Page 199: ...hrough 4095 The MAC to VLAN ID entry is enabled when you click on Save A mapping without any port members will not be added when you click Save The button can be used to undo the addition of new mappi...

Page 200: ...field the valid value of the following text field will vary depending on the new frame type you selected Value Valid value that can be entered in this text field depends on the option selected from t...

Page 201: ...roup Name A valid Group Name is a 16 character long string unique for every entry which consists of a combination of alphabets a z or A Z and integers 0 9 Note Special characters and underscores _ are...

Page 202: ...ne or more protocols inside that Group Furthermore the Group to VLAN ID mapping is not unique as long as the port lists of these mappings are mutually exclusive e g Group1 can be mapped to VID 1 on po...

Page 203: ...Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to save changes Click to undo any changes made locally and revert to previously sa...

Page 204: ...s the VLAN ID the subnet will be mapped to IP Subnet to VLAN ID is a unique matching Port Members A row of check boxes for each port is displayed for each IP subnet to VLAN ID mapping entry To include...

Page 205: ...Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to save changes Click to undo any changes made locally and revert to previously sa...

Page 206: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 206 VOICE VLAN CONFIGURATION VOICE VLAN CONFIGURATION Configuration Voice VLAN Configuration...

Page 207: ...ct mode is enabled In other cases it will be based on hardware aging time The actual aging time will be situated between the age_time 2 age_time interval Traffic Class Indicates the Voice VLAN traffic...

Page 208: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 208 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 209: ...deleted during the next save Telephony OUI A telephony OUI address is a globally unique identifier assigned to a vendor by IEEE It must be 6 characters long and the input format is xx xx xx x is a he...

Page 210: ...TOR MANUAL PAGE 210 ETHERNET SERVICES PORT CONFIGURATION Configuration Ethernet Services Ports This page displays current EVC port configurations The settings can also be configured here Port The logi...

Page 211: ...be based on the outer or inner tag This can be used on NNI ports connected to another service provider where an outer tunnel tag is added together with the inner tag identifying the EVC The allowed va...

Page 212: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 212 L2CP PORT CONFIGURATION Configuration Ethernet Services L2CP...

Page 213: ...and GARP 01 80 C2 00 00 2X MAC addresses for the settings contained in the same row L2CP Mode The L2CP mode for the specific port The possible values are Peer Allow to peer L2CP frames Forward Allow t...

Page 214: ...ports The settings can also be configured here Start Policer ID The start Policer ID for displaying the table entries The allowed range is from 1 through 256 Number of Entries The number of entries p...

Page 215: ...owed range is from 0 through 10000000 kilobit per second CBS The Committed Burst Size of the bandwidth profile The allowed range is from 0 through 100000 bytes EIR The Excess Information Rate for MEF...

Page 216: ...ssible values are Enabled Learning is enabled MAC addresses are learned Disabled Learning is disabled MAC addresses are not learned Inner Tag Type The inner tag type is used to determine whether an in...

Page 217: ...Tag DEI The inner tag DEI value The allowed value is 0 or 1 Outer Tag VID The EVC outer tag VID for UNI ports The allowed range is from 0 through 4095 NNI Ports The list of Network to Network Interfa...

Page 218: ...will match untagged frames only C Tagged The ECE will match custom tagged frames only S Tagged The ECE will match service tagged frames only Tagged The ECE will match tagged frames only VID The VLAN I...

Page 219: ...ECE does not map to an EVC Tag Pop Count The ingress tag pop count for the ECE The possible range is from 0 through 2 Policy ID The ACL Policy ID for the ECE The range is from 0 through 255 Class The...

Page 220: ...a new ECE before the current row Edits the ECE row Moves the ECE up the list Moves the ECE down the list Deletes the ECE The lowest plus sign adds a new entry at the bottom of the ECE listings Auto r...

Page 221: ...1 OSD2512 OPERATOR MANUAL PAGE 221 QOS QOS INGRESS PORT CLASSIFICATION Configuration QoS Port Classification This page allows you to configure the basic QoS Ingress Classification settings for all swi...

Page 222: ...nce level If the port is VLAN aware the frame is tagged and Tag Class is enabled then the frame is classified to a DPL that is mapped from the PCP and DEI value in the tag Otherwise the frame is class...

Page 223: ...SCP Based Click to Enable DSCP Based QoS Ingress Port Classification Address Mode The IP MAC address mode specifying whether the QCL classification must be based on source SMAC SIP or destination DMAC...

Page 224: ...nable or disable the port policer for this switch port Rate Controls the rate for the port policer This value is restricted to 100 3276700 when Unit is kbps or fps and 1 3276 when Unit is Mbps or kfps...

Page 225: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 225 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 226: ...IGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 226 QOS INGRESS QUEUE POLICERS Configuration QoS Queue Policing Buttons Click to save changes Click to undo any changes made locally and revert to prev...

Page 227: ...ler This page provides an overview of QoS Egress Port Schedulers for all switch ports The displayed settings are Port The logical port for the settings contained in the same row Click on the port numb...

Page 228: ...des an overview of QoS Egress Port Shapers for all switch ports The displayed settings are Port The logical port for the settings contained in the same row Click on the port number in order to configu...

Page 229: ...Egress Port Tag Remarking for all switch ports The displayed settings are Port The logical port for the settings contained in the same row Click on the port number in order to configure tag remarking...

Page 230: ...r all switch ports The displayed settings are Port The Port column shows the list of ports for which you can configure dscp ingress and egress settings Ingress In Ingress settings you can change ingre...

Page 231: ...f Disable No Egress rewrite Enable Rewrite enabled without remapping Remap DP Unaware DSCP from analyzer is remapped and frame is remarked with remapped DSCP value The remapped DSCP value is always ta...

Page 232: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 232 DSCP BASED QOS INGRESS CLASSIFICATION Configuration QoS DSCP Based QoS...

Page 233: ...of supported DSCP values are 64 Trust Controls whether a specific DSCP value is trusted Only frames with trusted DSCP values are mapped to a specific QoS class and Drop Precedence Level Frames with un...

Page 234: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 234 DSCP TRANSLATION Configuration QoS DSCP Translation...

Page 235: ...L SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 235 This page allows you to configure the basic QoS DSCP Translation settings for all switches DSCP translation can be done in Ingress or...

Page 236: ...n be translated to any of 0 63 DSCP values 2 Classify Click to enable Classification at Ingress side Egress There are the following configurable parameters for Egress side 1 Remap DP0 Controls the rem...

Page 237: ...pping of QoS class and Drop Precedence Level to DSCP value The displayed settings are QoS Class Actual QoS class DSCP DP0 Select the classified DSCP value 0 63 for Drop Precedence Level 0 DSCP DP1 Sel...

Page 238: ...AC address Possible values are Any Match any DMAC Unicast Match unicast DMAC Multicast Match multicast DMAC Broadcast Match broadcast DMAC The default value is Any SMAC Match specific source MAC addre...

Page 239: ...on taken on ingress frame if parameters configured are matched with the frame s content Possible actions are CoS Classify Class of Service DPL Classify Drop Precedence Level DSCP Classify DSCP value P...

Page 240: ...able The displayed settings are Frame Type The frame type for which the configuration below applies Enable Enable or disable the global storm policer for the given frame type Rate Controls the rate fo...

Page 241: ...MIRRORING AND REMOTE MIRRORING CONFIGURATION Configuration Mirroring Mirroring Remote Mirroring Configuration Mirroring is a feature for switched port analyzer The administrator can use the Mirroring...

Page 242: ...ct session id to configure MODE To Enabled Disabled the mirror or Remote Mirroring function TYPE Select switch type Mirror The switch is running on mirror mode The source port s and destination port a...

Page 243: ...d Note1 The Mirroring session shall have either ports or VLANs as sources but not both REMOTE MIRRORING PORT CONFIGURATION The following table is used for port role selecting Port The logical port for...

Page 244: ...p_inspection High disabled disabled acl Critical disabled disabled disabled dhcp_relay High disabled disabled dhcp_snooping High disabled disabled ip_source_guard Critical disabled disabled disabled i...

Page 245: ...S DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 245 High 5 packets 4 packets Low 5 packets 6 packets Buttons Click to save changes Click to undo any changes made locally and revert to previously...

Page 246: ...tion The duration carried in SSDP packets is used to inform a control point or control points how often it or they should receive an SSDP advertisement message from this switch If a control point does...

Page 247: ...in out put External Enable This Selection box will allow you to configure the External Clock output The following values are possible 1 True Enable the external clock output 2 False Disable the exter...

Page 248: ...ype is End to End Transparent Clock 4 Master Only clock s Device Type is Master Only 5 Slave Only clock s Device Type is Slave Only Profile Indicates the profile used by the clock Port List Set check...

Page 249: ...ich master clocks to request Announce and Sync messages from See Unicast Slave Configuration VID VLAN Identifier used for tagging the PTP frames Note Packets are tagged if the port is configured for v...

Page 250: ...ssing the Save button GVRP protocol timers Join time is a value in the range of 1 20cs i e in units of one hundredth of a second The default value is 20cs Leave time is a value in the range of 60 300c...

Page 251: ...iguration can be performed either before or after GVRP is configured globally the protocol operation will be the same Port The logical port that is to be configured Mode Mode can be either Disabled or...

Page 252: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 252 SFLOW CONFIGURATION Configuration sFlow...

Page 253: ...e If sFlow is currently configured through Web or CLI Owner contains Configured through local management If sFlow is currently configured through SNMP Owner contains a string identifying the sFlow rec...

Page 254: ...itch will automatically adjust it to the closest achievable This will be reported back in this field Valid range is 1 to 4294967295 Flow Sampler Max Header The maximum number of bytes that should be c...

Page 255: ...rations and possibly change them as well Port Port number of the switch UDLD Mode Configures the UDLD mode on a port Valid values are Disable Normal and Aggressive Default mode is Disable Disable In d...

Page 256: ...age Interval Configures the period of time between UDLD probe messages on ports that are in the advertisement phase and are determined to be bidirectional The range is from 7 to 90 seconds Default val...

Page 257: ...is provided here Contact The system contact configured in Configuration System Information System Contact Name The system name configured in Configuration System Information System Name Location The s...

Page 258: ...er running on the switch if any System Uptime The period of time the device has been operational Software Version The software version of this switch Software Date The date when the switch software wa...

Page 259: ...last 120 samples are graphed and the last numbers are displayed as text as well In order to display the SVG graph your browser must support the SVG format Consult the SVG Wiki for more information on...

Page 260: ...e IP protocol layer The status is defined by the IP interfaces the IP routes and the neighbour cache ARP cache status IP Interfaces Interface The name of the interface Type The address type of the ent...

Page 261: ...e gateway address of this route Status The status flags of the route Neighbour cache IP Address The IP address of the entry Link Address The Link MAC address for which a binding to the IP address give...

Page 262: ...ify which system log entries will be cleared To clear specific system log entries select the clear level first then click the button The Start from ID input field allow the user to change the starting...

Page 263: ...vel Time The occurred time of the system log entry Message The detail message of the system log entry Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs eve...

Page 264: ...f the system log entry ID The ID 1 of the system log entry Message The detailed message of the system log entry Buttons Updates the system log entry to the current entry ID Updates the system log entr...

Page 265: ...w Link Shows if the link is up for the port green link up red link down EEE cap Shows if the port is EEE capable EEE Ena Shows if EEE is enabled for the port reflects the settings at the Port Power Sa...

Page 266: ...s if the system is currently saving power due to ActiPhy PerfectReach Savings Shows if the system is currently saving power due to PerfectReach Buttons Auto refresh Check this box to refresh the page...

Page 267: ...ated to the fan control FAN STATUS Fan Speed Shows the speed that the fan is currently running at in RPM Rounds Per Minute Temperature Sensor Shows the temperature of the temperature sensor s in Celsi...

Page 268: ...on related to thermal protection Port The switch port number Temperature Shows the current chip temperature in degrees Celsius Port Status Shows if the port is thermally protected link is down or if t...

Page 269: ...s State This page provides an overview of the current switch port states The port states are illustrated as follows RJ45 ports SFP ports State Disabled Down Link Buttons Auto refresh Check this box to...

Page 270: ...ts The number of received and transmitted packets per port Bytes The number of received and transmitted bytes per port Errors The number of frames received in error and the number of incomplete transm...

Page 271: ...isplayed counters are Port The logical port for the settings contained in the same row Qn There are 8 QoS queues per port Q0 is the lowest priority queue Rx Tx The number of received and transmitted p...

Page 272: ...ates the QCE id Port Indicates the list of ports configured with the QCE Frame Type Indicates the type of frame Possible values are Any Match any frame type Ethernet Match EtherType frames LLC Match L...

Page 273: ...wise it is always No Please note that conflict can be resolved by releasing the H W resources required to add QCL entry on pressing Resolve Conflict button Buttons Select the QCL status from this drop...

Page 274: ...mit RECEIVE TOTAL AND TRANSMIT TOTAL Rx and Tx Packets The number of received and transmitted good and bad packets Rx and Tx Octets The number of received and transmitted good and bad bytes Includes F...

Page 275: ...with CRC or alignment errors Rx Undersize The number of short 1 frames received with valid CRC Rx Oversize The number of long 2 frames received with valid CRC Rx Fragments The number of short 1 frames...

Page 276: ...6 Buttons The port select box determines which port is affected by clicking the buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Clears th...

Page 277: ...mitted on this interface Event Notifications may be sent in duplicate to increase the probability of successfully being received given the possibility that a frame may be lost in transit Duplicate Eve...

Page 278: ...interface Rx and Tx Unsupported Codes A count of the number of OAMPDUs transmitted on this interface with an unsupported op code Rx and Tx Link fault PDU s A count of the number of Link fault PDU s r...

Page 279: ...itoring Support If status is enabled DTE supports interpreting Link Events MIB Retrieval Support If status ie enabled DTE supports sending Variable Response OAMPDUs MTU Size It represents the largest...

Page 280: ...o be parsed as nothing in it has changed PDU Permission This field is available only for the Local DTE It displays the current permission rules set for the local DTE Possible values are Link fault Rec...

Page 281: ...vent Timestamp This two octet field indicates the time reference when the event was generated in terms of 100ms intervals Frame error event window This two octet field indicates the duration of the pe...

Page 282: ...ince the OAM sublayer was reset Total frame period error events This four octet field indicates the number of Errored Frame Period Event TLVs that have been generated since the OAM sublayer was reset...

Page 283: ...tes the number of errored frame seconds in the period encoded as a 16 bit unsigned integer Event Seconds Summary Error Total This four octet field indicates the sum of errored frame seconds that have...

Page 284: ...PAGE 284 DHCP DHCP SERVER DHCP Server Statistics Monitor DHCP Server Statistics This page displays the database counters and the number of DHCP messages sent and received by DHCP server DATABASE COUNT...

Page 285: ...umber of bindings that their lease time expired or they are cleared from Automatic Manual type bindings DHCP MESSAGE RECEIVED COUNTERS Display counters of DHCP messages received by DHCP server DISCOVE...

Page 286: ...ERATOR MANUAL PAGE 286 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to clear HHCP Message Received Counters and DHCP Message Sen...

Page 287: ...atic Manual Expired State State of binding Possible states are Committed Allocated Expired Pool Name The pool that generates the binding Server ID Server IP address to service the binding Buttons Auto...

Page 288: ...18101 OSD2512 OPERATOR MANUAL PAGE 288 Click to clear all Automatic bindings and Change them to Expired bindings Click to clear all Manual bindings and Change them to Expired bindings Click to clear a...

Page 289: ...ver Binding This page displays declined IP addresses DECLINED IP ADDRESSES Display IP addresses declined by DHCP clients Declined IP List of IP addresses declined Buttons Auto refresh Check this box t...

Page 290: ...ries from the beginning of the Dynamic DHCP snooping Table The MAC address and VLAN input fields allows the user to select the starting point in the Dynamic DHCP snooping Table Clicking the button wil...

Page 291: ...er address of the entry Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Flus...

Page 292: ...s Receive Missing Circuit ID The number of packets received with the Circuit ID option missing Receive Missing Remote ID The number of packets received with the Remote ID option missing Receive Bad Ci...

Page 293: ...ption Keep Agent Option The number of packets whose relay agent information was retained Drop Agent Option The number of packets that were dropped which were received with relay agent information Butt...

Page 294: ...KETS Rx and Tx Discover The number of discover option 53 with value 1 packets received and transmitted Rx and Tx Offer The number of offer option 53 with value 2 packets received and transmitted Rx an...

Page 295: ...s received and transmitted Rx and Tx Lease Active The number of lease active option 53 with value 13 packets received and transmitted Rx Discarded checksum error The number of discard packet that IP U...

Page 296: ...switch Received Packets Number of received packets from the interface when access management mode is enabled Allowed Packets Number of allowed packets from the interface when access management mode is...

Page 297: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 297 NETWORK Port Security Port Security Switch Status Monitor Security Network Port Security Switch...

Page 298: ...dule This is used in the Users column in the port status table PORT STATUS The table has one row for each port on the switch and a number of columns which are Port The port number for which the status...

Page 299: ...r of MAC addresses that can be learned on the port respectively If no user modules are enabled on the port the Current column will show a dash If the Limit Control user module is not enabled on the po...

Page 300: ...a single row stating No MAC addresses attached is displayed State Indicates whether the corresponding MAC address is blocked or forwarding In the blocked state it will not be allowed to transmit or r...

Page 301: ...detailed NAS statistics for this port Admin State The port s current administrative state Refer to NAS Admin State for a description of possible values Port State The current state of the port Refer t...

Page 302: ...d to the port by the RADIUS server if enabled Port VLAN ID The VLAN ID that NAS has put the port in The field is blank if the Port VLAN ID is not overridden by NAS If the VLAN ID is assigned by the RA...

Page 303: ...e current state of the port Refer to NAS Port State for a description of the individual states QoS Class The QoS class assigned by the RADIUS server The field is blank if no QoS class is assigned Port...

Page 304: ...have been received by the switch Rx Invalid Type dot1xAuthInvalidEapolFramesRx The number of EAPOL frames that have been received by the switch in which the frame type is not recognized Rx Invalid Le...

Page 305: ...itch sends an EAP Request packet following the first to the supplicant Indicates that the backend server chose an EAP method MAC based Not applicable Rx Auth Successes dot1xAuthBackendAuthSuccesses 80...

Page 306: ...Source The MAC address of the last supplicant client VLAN ID The VLAN ID on which the last frame from the last supplicant client was received Version dot1xAuthLastEapolFrameVersion 802 1X based The pr...

Page 307: ...y secured through the Port Security module State The client can either be authenticated or unauthenticated In the authenticated state it is allowed to forward frames on the port and in the unauthentic...

Page 308: ...based Auth X Click to clear both the port counters and all of the attached client s counters The Last Client will not be cleared however This button is available in the following modes Multi 802 1X MA...

Page 309: ...ill not get matched by IP and ARP frames ARP The ACE will match ARP RARP frames IPv4 The ACE will match all IPv4 frames IPv4 ICMP The ACE will match IPv4 frames with ICMP protocol IPv4 UDP The ACE wil...

Page 310: ...ct Indicates the hardware status of the specific ACE The specific ACE is not applied to the hardware due to hardware limitations Buttons The select box determines which ACL user is affected by clickin...

Page 311: ...spection Table The Start from port address VLAN MAC address and IP address input fields allow the user to select the starting point in the Dynamic ARP Inspection Table Clicking the button will update...

Page 312: ...to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Flushes all dynamic entries Updates the table starting from the first entry in the Dyna...

Page 313: ...le The Start from port address VLAN and IP address input fields allow the user to select the starting point in the Dynamic IP Source Guard Table Clicking the button will update the displayed table sta...

Page 314: ...Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Flushes all dynamic entries Updates the table starting from the first e...

Page 315: ...cation is not yet up and running Ready The server is enabled IP communication is up and running and the RADIUS module is ready to accept access attempts Dead X seconds left Access attempts were made t...

Page 316: ...configured timeout The server has temporarily been disabled but will get re enabled when the dead time expires The number of seconds left before this occurs is displayed in parentheses This state is o...

Page 317: ...s Monitor Security AAA RADIUS Details This page provides detailed statistics for a particular RADIUS server RADIUS AUTHENTICATION STATISTICS The statistics map closely to those specified in RFC4668 RA...

Page 318: ...d RADIUS Access Response packets received from the server Malformed packets include packets with an invalid length Bad authenticators or Message Authenticator attributes or unknown types are not inclu...

Page 319: ...the same server is counted as a retransmit as well as a timeout A send to a different server is counted as a Request as well as a timeout Other Info This section contains information about the state...

Page 320: ...the server Rx Malformed Responses radiusAccClientExtMalformedResponses The number of malformed RADIUS packets received from the server Malformed packets include packets with an invalid length Bad aut...

Page 321: ...following values Disabled The selected server is disabled Not Ready The server is enabled but IP communication is not yet up and running Ready The server is enabled IP communication is up and running...

Page 322: ...PAGE 322 Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Clears the counters for the selected server The P...

Page 323: ...the lowest ID found in the Statistics table The Start from Control Index allows the user to select the starting point in the Statistics table Clicking the button will update the displayed table starti...

Page 324: ...t Error Under size The total number of packets received that were less than 64 octets Over size The total number of packets received that were longer than 1518 octets Frag The number of frames which s...

Page 325: ...to 1588 octets in length Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table startin...

Page 326: ...update the displayed table starting from that or the next closest History table match The will use the last entry of the currently displayed entry as a basis for the next lookup When the end is reache...

Page 327: ...n 64 octets Oversize The total number of packets received that were longer than 1518 octets Frag The number of frames which size is less than 64 octets received with invalid CRC Jabb The number of fra...

Page 328: ...oint in the Alarm table Clicking the button will update the displayed table starting from that or the next closest Alarm table match The will use the last entry of the currently displayed entry as a b...

Page 329: ...t index Falling Threshold Falling threshold value Falling Index Falling event index Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click...

Page 330: ...Index and Log Index found in the Event table The Start from Event Index and Log Index allows the user to select the starting point in the Event table Clicking the button will update the displayed tab...

Page 331: ...s box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table starting from the first entry in the Event Table i e the entry...

Page 332: ...associated with this aggregation instance Name Name of the Aggregation group ID Type Type of the Aggregation group Static or LACP Speed Speed of the Aggregation group Configured ports Configured membe...

Page 333: ...id is shown as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID La...

Page 334: ...ACP is not enabled or that the port link is down Backup means that the port could not join the aggregation group but will join if other port leaves Meanwhile it s LACP status is disabled Key The key a...

Page 335: ...STEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 335 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page i...

Page 336: ...switch port number LACP Received Shows how many LACP frames have been received at each port LACP Transmitted Shows how many LACP frames have been sent from each port Discarded Shows how many unknown o...

Page 337: ...port Action The currently configured port action Transmit The currently configured port transmit mode Loops The number of loops detected on this port Status The current loop protection status of the...

Page 338: ...nce This is also a link to the STP Detailed Bridge Status Bridge ID The Bridge ID of this Bridge instance Root ID The Bridge ID of the currently elected root bridge Root Port The switch port currently...

Page 339: ...STEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 339 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page i...

Page 340: ...rent STP port role of the CIST port The port role can be one of the following values AlternatePort BackupPort RootPort DesignatedPort Disabled CIST State The current STP port state of the CIST port Th...

Page 341: ...mber of RSTP BPDU s received transmitted on the port STP The number of legacy STP Configuration BPDU s received transmitted on the port TCN The number of legacy Topology Change Notification BPDU s rec...

Page 342: ...MLD respectively IGMPv1 Joins Received The number of Received IGMPv1 Join s IGMPv2 MLDv1 Report s Received The number of Received IGMPv2 Join s and MLDv1 Report s respectively IGMPv3 MLDv2 Report s Re...

Page 343: ...Table The Start from VLAN and Group Address input fields allow the user to select the starting point in the MVR Channels Groups Information Table Clicking the button will update the displayed table st...

Page 344: ...refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the MVR Channel...

Page 345: ...first visited the web page will show the first 20 entries from the beginning of the MVR SFM Information Table The Start from VLAN and Group Address input fields allow the user to select the starting...

Page 346: ...e is shown in the Source Address field Type Indicates the Type It can be either Allow or Deny Hardware Filter Switch Indicates whether data plane destined to the specific group address from the source...

Page 347: ...8101 OSD2512 OPERATOR MANUAL PAGE 347 IPMC IGMP SNOOPING IGMP Snooping Status Monitor IPMC IGMP Snooping Status This page provides IGMP Snooping status VLAN ID The VLAN ID of the entry Querier Version...

Page 348: ...3 Reports V2 Leaves Received The number of Received V2 Leaves Router Port Display which ports act as router ports A router port is a port on the Ethernet switch that leads towards the Layer 3 multicas...

Page 349: ...able The Start from VLAN and group input fields allow the user to select the starting point in the IGMP Group Table Clicking the button will update the displayed table starting from that or the closes...

Page 350: ...refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the MVR Channel...

Page 351: ...first visited the web page will show the first 20 entries from the beginning of the IGMP SFM Information Table The Start from VLAN and group input fields allow the user to select the starting point i...

Page 352: ...s shown in the Source Address field Type Indicates the Type It can be either Allow or Deny Hardware Filter Switch Indicates whether data plane destined to the specific group address from the source IP...

Page 353: ...ID of the entry Querier Version Working Querier Version currently Host Version Working Host Version currently Querier Status Shows the Querier status is ACTIVE or IDLE DISABLE denotes the specific in...

Page 354: ...3 multicast device or MLD querier Static denotes the specific port is configured to be a router port Dynamic denotes the specific port is learnt to be a router port Both denote the specific port is c...

Page 355: ...le The Start from VLAN and group input fields allow the user to select the starting point in the MLD Group Table Clicking the button will update the displayed table starting from that or the closest n...

Page 356: ...this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the...

Page 357: ...first visited the web page will show the first 20 entries from the beginning of the MLD SFM Information Table The Start from VLAN and group input fields allow the user to select the starting point in...

Page 358: ...None is shown in the Source Address field Type Indicates the Type It can be either Allow or Deny Hardware Filter Switch Indicates whether data plane destined to the specific group address from the sou...

Page 359: ...Interface The interface on which the LLDP frame was received Chassis ID The Chassis ID is the identification of the neighbor s LLDP frames Port ID The Port ID is the identification of the neighbor por...

Page 360: ...apability is disabled the capability is followed by Management Address Management Address is the neighbor unit s address that is used for higher layer entities to assist discovery by the network manag...

Page 361: ...h Router 2 IEEE 802 1 Bridge 3 IEEE 802 3 Repeater included for historical reasons 4 IEEE 802 11 Wireless Access Point 5 Any device that supports the IEEE 802 1AB and MED extensions defined by TIA 105...

Page 362: ...Discovery services defined in this class include media type specific network layer policy discovery LLDP MED Communication Endpoint Class III The LLDP MED Communication Endpoint Class III definition...

Page 363: ...tribution and other similar applications supporting streaming video services that require specific network policy treatment Video applications relying on TCP with buffering would not be an intended us...

Page 364: ...identifies if MAC PHY auto negotiation is supported by the link partner Auto negotiation status Auto negotiation status identifies if auto negotiation is currently enabled at the link partner If Auto...

Page 365: ...terface does not supports EEE then it displays as EEE not supported for this interface If EEE is not enabled on particular interface then it displays as EEE not enabled for this interface If the link...

Page 366: ...not match the values in its local MIB then the local link partner infers that the remote link partners request was based on stale information Echo Rx Tw The link partner s Echo Rx Tw value Resolved Tx...

Page 367: ...ounters If checked the global counters are cleared when is pressed Neighbor entries were last changed Shows the time when the last entry was last deleted or added It also shows the time elapsed since...

Page 368: ...re removed from the table when a given interface s link is down an LLDP shutdown frame is received or when the entry ages out TLVs Discarded Each LLDP frame can contain multiple pieces of information...

Page 369: ...ters for UNI ports of ECEs mapping to the EVC And the MPLS Pseudo Wires counters are included when the PW ID is attached to the selected EVC Class The traffic class for the EVC Rx Green The number of...

Page 370: ...mber of discarded in the yellow color Buttons The port select box determines which port is affected by clicking the buttons Auto refresh Check this box to refresh the page automatically Automatic refr...

Page 371: ...output configuration 1 True Enable the external clock output 2 False Disable the external clock output Adjust Method Shows the current Frequency adjustment configuration 1 LTC frequency Local Time Cou...

Page 372: ...the Clock Instance There are five Device Types 1 Ord Bound Clock s Device Type is Ordinary Boundary Clock 2 P2p Transp Clock s Device Type is Peer to Peer Transparent Clock 3 E2e Transp Clock s Devic...

Page 373: ...GN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 373 MAC TABLE Monitor MAC Table Entries in the MAC Table are shown on this page The MAC Table contains up to 8192 entries and is sorted first by VLAN ID...

Page 374: ...splayed entry allowing for continuous refresh with the same start address The will use the last entry of the currently displayed VLAN MAC address pairs as a basis for the next lookup When the end is r...

Page 375: ...ID for which the Port members are displayed Port Members A row of check boxes for each port is displayed for each VLAN ID If a port is included in a VLAN the following image will be displayed If a po...

Page 376: ...e last entry of the currently displayed VLAN entry as a basis for the next lookup When the end is reached the text No data exists for the selected user is shown in the table Use the button to start ov...

Page 377: ...iguration and basically reflects what is actually configured in hardware If a given software modules hasn t overridden any of the port settings the text No data exists for the selected user is shown i...

Page 378: ...licts Two users may have conflicting requirements to a port s configuration For instance one user may require all frames to be tagged on egress while another requires all frames to be untagged on egre...

Page 379: ...FLOW STATISTICS Monitor sFlow This page shows receiver and per port sFlow statistics RECEIVER STATISTICS Owner This field shows the current owner of the sFlow configuration It assumes one of three val...

Page 380: ...ource of errors is invalid sFlow receiver IP hostname configuration To diagnose paste the receiver s IP address hostname into the Ping Web page Diagnostics Ping Ping6 Flow Samples The total number of...

Page 381: ...he ports UDLD PORT STATUS UDLD Admin State The current port state of the logical port Enabled if any of state Normal Aggressive is Enabled Device ID local The ID of Device Device Name local Name of th...

Page 382: ...link status of neighbor port Device Name Name of the Neighbor Device Buttons The port select box determines which port is affected by clicking the buttons Auto refresh Check this box to refresh the pa...

Page 383: ...ECHO_REPLY will always be 8 bytes more than the requested data space the ICMP header The page refreshes automatically until responses to all packets are received or until a timeout occurs PING server...

Page 384: ...ieve the local or remote OAM MIB variable data on a particular port Select the appropriate radio button and enter the port number of the switch to retrieve the content of interest Click on to retrieve...

Page 385: ...47 icmp_seq 1 time 0ms 64 bytes from fe80 215 58ff feed 69dd icmp_seq 1 time 0ms 64 bytes from fe80 219 5bff fe2f b47 icmp_seq 2 time 0ms 64 bytes from fe80 215 58ff feed 69dd icmp_seq 2 time 0ms 64 b...

Page 386: ...4094 and will be effective only when the corresponding IPv6 interface is valid When the egress interface is not given PING6 finds the best match interface for destination Do not specify egress interf...

Page 387: ...take approximately 15 seconds When completed the page refreshes automatically and you can view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of...

Page 388: ...B Cross pair short to pair B Short C Cross pair short to pair C Short D Cross pair short to pair D Cross A Abnormal cross pair coupling with pair A Cross B Abnormal cross pair coupling with pair B Cr...

Page 389: ...TOR MANUAL PAGE 389 9 5 MAINTENANCE RESTART DEVICE Maintenance Restart Device You can restart the switch on this page After restart the switch will boot normally Buttons Click to restart device Click...

Page 390: ...means that no restart is necessary Buttons Click to reset the configuration to Factory Defaults Click to return to the Port State page without restarting Note Restoring factory default can also be pe...

Page 391: ...ick After the software image is uploaded a page announces that the firmware update is initiated After about a minute the firmware is updated and the switch restarts Warning While the firmware is being...

Page 392: ...ate Image button is also disabled 2 If the alternate image is active due to a corruption of the primary image or by manual intervention uploading a new firmware image to the device will automatically...

Page 393: ...tly active configuration on the switch This file is volatile startup config The startup configuration for the switch read at boot time If this file doesn t exist at boot time the switch will start up...

Page 394: ...94 DOWNLOAD CONFIGURATION Maintenance Configuration Download It is possible to download any of the files on the switch to the web browser Select the file and click Download of running config may take...

Page 395: ...then click If the destination is running config the file will be applied to the switch configuration This can be done in two ways Replace mode The current configuration is fully replaced with the conf...

Page 396: ...n Activate It is possible to activate any of the configuration files present on the switch except for running config which represents the currently active configuration Select the file to activate and...

Page 397: ...CONFIGURATION FILE Maintenance Configuration Delete It is possible to delete any of the writable files stored in flash including startup config If this is done and the switch is rebooted without a pr...

Page 398: ...d representative for all repairs WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense OUT OF WARRANTY REPAIRS OSD reserves th...

Page 399: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 399...

Page 400: ...OPTICAL SYSTEMS DESIGN DOC ID 10118101 OSD2512 OPERATOR MANUAL PAGE 400...

Page 401: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...