Lift the battery
1
from the compartment.
4
Disconnect the battery from the battery connector
2
.
2
1
5
Connect the new battery to the battery connector.
6
Place the new battery in the Box PC.
Ensure the wires are at the side of the battery and not on top of the battery. If the wires are on
top of the battery this might make closing and opening the cover more difficult.
7
Write the next date of replacement on the label at the inside of the cover.
Additional Information
Refer to
on page 3-20 for lifetime of the battery.
8
Mount the cover.
9
Remove the power connector for at least 3 seconds to reset the battery warning.
10
Power ON the Box PC.
11
Check the Date and Time in the operating system.
Correct the Date and Time if this is required.
The battery is replaced and the alarm is reset.
7 Maintenance
7-10
NY-series Industrial Box PC Hardware User's Manual (W553)
Summary of Contents for SYSMAC NY Series
Page 4: ...Introduction 2 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 10: ...Index CONTENTS 8 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 32: ...Revision History 30 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 74: ...3 Hardware 3 32 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 114: ...4 Specifications 4 40 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 168: ...5 Installation 5 54 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 198: ...7 Maintenance 7 24 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 254: ...Appendices A 56 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 255: ...I Index I 1 NY series Industrial Box PC Hardware User s Manual W553 I ...
Page 258: ...Index I 4 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 259: ......