I/O Connector Wiring Procedure
Use the following procedure to wire the I/O connector.
1
Ensure the I/O connector is not connected to the Box PC.
2
Remove the sheath from the wires.
7 mm
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
3
Remove the I/O connector from the Box PC.
4
Insert a screwdriver in the small groove above the cable entry
1
to unlock the cable entry and
then push the wire all the way to the back of the cable opening
2
.
1
2
5
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
5 Installation
5-38
NY-series Industrial Box PC Hardware User's Manual (W553)
Summary of Contents for SYSMAC NY Series
Page 4: ...Introduction 2 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 10: ...Index CONTENTS 8 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 32: ...Revision History 30 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 74: ...3 Hardware 3 32 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 114: ...4 Specifications 4 40 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 168: ...5 Installation 5 54 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 198: ...7 Maintenance 7 24 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 254: ...Appendices A 56 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 255: ...I Index I 1 NY series Industrial Box PC Hardware User s Manual W553 I ...
Page 258: ...Index I 4 NY series Industrial Box PC Hardware User s Manual W553 ...
Page 259: ......