PART 2: CX-Server PLC Tools
OMRON
CHAPTER 10 – Data Links
CX-Server PLC Tools_ Page 93
Toolbar
(1) (2) (3) (4)
(5) (6) (7) (8) (9) (10) (11)
(12) (13) (14) (15)
(16) (17)
(18)
(19) (20)
No. Icon
Function
(1)
New
Creates new data link tables.
(2)
Show All Network Nodes
Shows all nodes in the network.
(3)
Opens a data link tables, Files with any of the file name
extensions shown below can be opened.
When a file is opened, the proper editor starts up.
Controller Link
.cl2 – CX-Net Controller Link/CLKSS data link tables
.cl3 – CX-Net Controller Link data link tables
.clk – CLKSS data link tables
.csv – CX-Net Controller Link data link tables (tab-delineated
text file)
Open
SYSMAC LINK
.sl3 – SYSMAC LINK data link tables
.slk – SYSMAC LINK data link tables for SYSMAC Support
Software
.csv – SYSMAC LINK data link tables (tab-delineated text
file)
(4)
Save
Saves the data link tables that are being edited.
(5)
Toggle Network/Single Node
Operation
Specifies either all nodes or a single node for data transfers.
(6)
Transfer to PLC
Downloads online data link tables from the computer to a PLC.
(7)
Transfer from PLC
Uploads online data link tables to the computer.
(8)
Delete
Deletes data link tables.
(9)
Verify Node
Compares data link tables generated by CX-Net with data link
tables stored in the PLC. If they do not match, a error dialog box
is displayed.
(10)
Data Link Operation/Status
Displays the operation and data link status of manually set data
links.
(11)
Automatic Data Link Setup
Sets parameters for automatically set data links, and transfers
them to the startup node.
(12)
Validate Table
Checks data link tables.
(13)
Wizard
Executes the Datalink Wizard.
(14)
Add Source Link
Adds a node to the data links.
(15)
Add Destination
Adds the receive area of a participating node to the data links.
(16)
Set Source or Destination
Link Area Properties
Displays the Node Settings dialog box. This dialog box is used
to modify the node properties.
(17)
Delete Link Destination
Service Area
Deletes nodes selected in the Data Link Configuration window,
or deletes a receive area.
(18)
Zoom In/Zoom Out/Zoom
Original
Zooms the Data Link Configuration window in or out, or returns
it to the initial scale.
(19)
Prints data link information.
(20) Help
Displays
help.
Summary of Contents for CX-Programmer 9
Page 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Page 4: ......
Page 6: ......
Page 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Page 30: ......
Page 31: ...PART 1 CX Programmer...
Page 32: ......
Page 100: ......
Page 120: ......
Page 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Page 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Page 240: ......
Page 241: ...PART 2 CX Server PLC Tools...
Page 242: ......
Page 250: ......
Page 256: ......
Page 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 286: ......
Page 338: ......
Page 382: ......
Page 414: ......
Page 430: ......
Page 436: ......
Page 437: ...PART 3 CX Server Runtime...
Page 438: ......
Page 482: ......
Page 488: ......
Page 504: ......
Page 530: ......
Page 540: ......
Page 541: ......
Page 542: ......